User manual

The device is in normal mode (no signal). To perform the
functional check press and release the button (< 2 s). (6) ->
Siren sounds 3 times ≥85 dB(A), LED flashes red, emergency
light on. Then LED flashes red once every 10 s (muted). After
10 min the device will switch to normal mode again.
If the functional check fails the device is defective and must be
replaced.
Siren off (alarm signal)
LED of the device that triggered an alarm flashes red fast.
If you press and release the button (< 2 s) of a device that
has triggered an alarm, then all devices stop sounding and
emergency light turns off (delay up to 16 s).
If you press and release the button (< 2 s) of another device
in the network, then all devices (except the device that
triggered the alarm) stop sounding and emergency light turns
off (delay up to 16 s).
After turning the siren off, the LED of the device that has
triggered the alarm flashes red once every 10 s (muted). After
10 min the device will switch to normal mode again.
Polluted smoke chamber/weak battery
If the siren sounds short 3 times every 43 s (polluted smoke
chamber), then you have to replace the device. If the siren
sounds short once every 43 s (weak battery), also then you have
to replace the device.
If the siren sounds short once every 3 h the device indicates
weak battery of another device in the network. The device with
weak battery sounds every 43 s and must be replaced.
Wireless Smoke Alarm
Graphics | en 13