Wireless Smoke Alarm FERION 5000 OW en
Wireless Smoke Alarm Table of Contents | en 3 Table of contents 1 Graphics 4 2 Introduction 6 3 Mounting 7 4 Radio Network 9 5 Maintenance 12 6 Technical data 14 7 Customer Service 16 Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.
en | Graphics Wireless Smoke Alarm 1 Graphics minimum (1) additional unsuitable R R repeater ON (2.A) (2.B) (2.C) (2.D) ≤1m >1m m 1 5- 0. 1m 50. 0-20° 0.5m >20° 08.15 | 2.1 | F.01U.309.
Wireless Smoke Alarm Graphics | en (3) 1 x 3 mm (5) 2 5 1 A A 1 B 2 x 3 mm 2 60 mm B (4) 1 1 3 1 2 4 (6) (7) <2s Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.
en | Graphics Wireless Smoke Alarm 2 Introduction The FERION 5000 OW wireless smoke alarm device with built‑in long-life battery, built‑in siren (4.1), alarm LED (4.2), emergency light (4.3) and big button for operation (4.4) is solely designed for residential applications. The device reliably warns you of the emergence of a fire in your house or flat. If the smoke emissions exceed a certain limit, an alarm is raised. More information, CE declaration, and declaration of performance is available on www.
Wireless Smoke Alarm Graphics | en 7 Notice! Do not use if there are signs of damage, or in case of malfunction. Return defective devices to the place of purchase. Not suitable for household room illumination! Old devices are not to be disposed of with the household waste. Dispose of them according to the guidelines for electric and electronic waste at the local collection points. Parts included 1 smoke alarm device: base (3.A) and detector head (3.
en | Graphics Wireless Smoke Alarm mounted horizontally on the ceiling in centered position with a minimum distance of 0.5m to walls and objects. On slanted ceilings >20° it is to be mounted 0.5m to 1m from the top of the ceiling. (2.A), (2.B), (2.C), (2.D) 2. Connecting devices, page 10. For testing the network, position the devices near to the determined mounting locations: Testing the network, page 10. If necessary switch the repeater function on for one device, see Repeater function, page 11. 3.
Wireless Smoke Alarm Graphics | en 9 Mounting the base Mount the base with one central screw and plug. (5.A) Or optionally use two screws and plugs. (5.B) To set the device into operation you screw the detector head to its base by twisting it clockwise until it latches. (6) 4 Radio Network Up to 40 FERION 5000 OW can be interconnected to create a network. Thus, an alarm is raised at all devices giving the chance to react faster to a distant fire.
en | Graphics Wireless Smoke Alarm Attentively read the following instructions before programming. Connecting devices If the device which you want to connect was not in use before proceed with step 1. If the device which you want to connect was already in use, disassemble head and base. Then press and hold the button for about 4 s to clear for installation. If it was already element of a network, then reset it first, see Disconnecting a device (Reset), page 12. 1.
Wireless Smoke Alarm Graphics | en 11 After short delay all devices in the network flash green 5 min (no audible signal). If not, the connecting procedure failed or the distance between the connected devices is too large (the connected devices cannot reach each other). To extend the operating range switch the repeater function on. To stop the flashing earlier you press and hold the button for about 10 s.
en | Graphics Wireless Smoke Alarm 2. Press and hold the button for about 4 s. -> The LED lights up red (repeater function off) or green (repeater function on) for 30 s. To change the mode of the repeater function press and release the button (< 2 s). -> LED changes the color promptly. After 30 s the device will switch to normal mode again. Adding devices to an existing network Perform Connecting devices, page 10 for one device of the existing network and the unprogrammed device.
Graphics | en Wireless Smoke Alarm – 13 The device is in normal mode (no signal). To perform the functional check press and release the button (< 2 s). (6) -> Siren sounds 3 times ≥85 dB(A), LED flashes red, emergency light on. Then LED flashes red once every 10 s (muted). After 10 min the device will switch to normal mode again. If the functional check fails the device is defective and must be replaced. Siren off (alarm signal) LED of the device that triggered an alarm flashes red fast.
en | Graphics Wireless Smoke Alarm 6 Technical data Sound pressure level at a distance of 3 m in ≥85 dB(A) Power supply (2 x 3V, non-replaceable) LiMnO2 Dimensions (diameter x height, mm) 119 x 50 Weight (g) 167 Protection category (EN 60529) IP20 Operating temp. (°C)* 0 … +45 Storage temp. (°C)* -10 … +55 Max. rel.
Wireless Smoke Alarm Graphics | en Certification CE , VdS , Q-Label Harmonized standards EN 14604:2009-02 15 1999/5/EC Wireless operation Transmission band (MHz) 868.3 Receiver category (SRD Class) 2 Duty Cycle (%/h) 1 Range in free field (repeater function off, m) ≤100 Max. no.
en | Graphics Wireless Smoke Alarm Mode Optical Audible Weak battery flashes red 1 x / 43 s 1 x short / 43 s Polluted smoke flashes red 3 x / 43 s 3 x short / 43 s chamber Signals in wireless operation Mode Optical Audible Alarm from another emergency light 3 x ≥85 dB(A) / 4 device s Network test OK flashes green 5 min Weak battery of flashes red 1 x / 3 h 1 x short / 3 h another device LED test LED change: red, - green, orange 7 Customer Service Replacement of the product is
Wireless Smoke Alarm Graphics | en Great Britain Ireland Robert Bosch Ltd. (B.S.C.) Origo Ltd. P.O. Box 98 Unit 23 Magna Drive Broadwater Park Magna Business Park North Orbital Road City West Denham Dublin 24 Uxbridge Tel. Service: UB 9 5HJ (01) 4666700 Tel. Service: Fax: (01) 4666888 17 (0344) 7360109 E-Mail: boschservicecentre@bosch.co m Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.
Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.