Smoke Alarm FERION 4000 O en
Smoke Alarm Table of Contents | en 3 Table of contents 1 Graphics 4 2 Introduction 6 3 Mounting 7 4 Maintenance 5 Technical data 10 6 Customer Service 11 Bosch Sicherheitssysteme GmbH 9 08.15 | 2.1 | F.01U.309.
en | Graphics Smoke Alarm 1 Graphics minimum (1) additional unsuitable (2.A) 5- 0. (2.B) (2.C) (2.D) ≤1m >1m 1m m -1 0-20° 5 0. 0.5m >20° 08.15 | 2.1 | F.01U.309.
Smoke Alarm Graphics | en (3) 1 x 3 mm (5) 2 5 1 A A 1 B 2 x 3 mm 2 60 mm B (4) 1 1 3 1 2 4 (6) (7) <2s Bosch Sicherheitssysteme GmbH 08.15 | 2.1 | F.01U.309.
en | Graphics Smoke Alarm 2 Introduction The FERION 4000 O smoke alarm device with built‑in long-life battery, built‑in siren (4.1), alarm LED (4.2), emergency light (4.3) and big button for operation (4.4) is solely designed for residential applications. The device reliably warns you of the emergence of a fire in your house or flat. If the smoke emissions exceed a certain limit, an alarm is raised. More information, CE declaration, and declaration of performance is available on www.boschsecurity.
Smoke Alarm Graphics | en 7 Notice! Do not use if there are signs of damage, or in case of malfunction. Return defective devices to the place of purchase. Not suitable for household room illumination! Old devices are not to be disposed of with the household waste. Dispose of them according to the guidelines for electric and electronic waste at the local collection points. Parts included 1 smoke alarm device: base (3.A) and detector head (3.
en | Graphics Smoke Alarm mounted horizontally on the ceiling in centered position with a minimum distance of 0.5m to walls and objects. On slanted ceilings >20° it is to be mounted 0.5m to 1m from the top of the ceiling. (2.A), (2.B), (2.C), (2.D) 2. For each device: Mounting the base. (5) Observe the mark (5.2) for adjusting the emergency light and the marks (5.1) for alignment with BOSCH label/siren. 3. Functional check, page 9, for each device after setting it up into operation.
Graphics | en Smoke Alarm 9 4 Maintenance Functional check A visual inspection and a functional check must be done for each device monthly. After the functional check the device is muted for 10 min, even when an alarm will be triggered. – The device is in normal mode (no signal). To perform the functional check press and release the button (< 2 s). (6) -> Siren sounds 3 times ≥85 dB(A), LED flashes red, emergency light on. Then LED flashes red once every 10 s (muted).
en | Graphics Smoke Alarm 5 Technical data Sound pressure level at a distance of 3m in ≥85 dB(A) Power supply (2 x 3V, non-replaceable LiMnO2 batteries) Dimensions (diameter x height, mm) 119 x 50 Weight (g) 134 Protection category (EN 60529) IP20 Operating temperature (°C)* 0 … +45 Storage temperature (°C)* -10 … +55 Relative humidity (%, noncondensing) 93 Guarantee without batteries (y)** 10 Typical battery lifetime (y)*** 10 * high temperature (> +30 °C) reduce the battery lifet
Smoke Alarm Graphics | en Certification CE , VdS , Q-Label Harmonized standards EN 14604:2009-02 11 Signals Mode Optical Audible Normal - - Functional test OK flashes red fast, 3 x ≥85 dB(A) emergency light Alarm Muted flashes red fast, 3 x ≥85 dB(A) / 4 emergency light s flashes red 1 x / 10 s - for 10 min Weak battery flashes red 1 x / 43 s 1 x short / 43 s Polluted smoke flashes red 3 x / 43 s 3 x short / 43 s chamber 6 Customer Service Replacement of the product is only po
en | Graphics Smoke Alarm Great Britain Ireland Robert Bosch Ltd. (B.S.C.) Origo Ltd. P.O. Box 98 Unit 23 Magna Drive Broadwater Park Magna Business Park North Orbital Road City West Denham Dublin 24 Uxbridge Tel. Service: UB 9 5HJ (01) 4666700 Tel. Service: Fax: (01) 4666888 (0344) 7360109 E-Mail: boschservicecentre@bosch.co m 08.15 | 2.1 | F.01U.309.
Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.