High Speed Pan/Tilt System UPH-2D, UPH-3D, UPH-Z Series en Instruction Manual
High Speed Pan/Tilt System Table of Contents | en 3 Table of Contents 1 Safety 5 1.1 Important safety instructions 5 1.2 Safety precautions 6 1.3 Important notices 7 2 Unpacking 9 2.1 Parts List 9 2.2 Tools Required 9 2.3 Safety Rules 10 3 Description 10 4 Installing the High Speed Pan/Tilt 11 4.1 Mounting the High Speed Pan/Tilt 11 4.2 Wiring the Video Cable 14 4.3 Connecting the Power Supply 15 4.4 Wiring Biphase 16 4.
en | Table of Contents High Speed Pan/Tilt System 11 Configuring the System 34 11.1 Language Menu 35 11.2 Display Setup Menu 35 11.2.1 Area Parameters Menu 37 11.2.2 Changing the Edit Text Menu 38 11.2.3 Display Parameters 39 11.3 Motion Parameters Menu 40 11.3.1 Speed Menu 40 11.3.2 Limits 42 11.3.3 Preset/Patrol/Autopan 43 11.3.4 Wiper-Washer 49 11.3.5 Alarms 50 11.4 Camera Parameters 50 (DinionXF 11.4.1 UPH-2D and UPH-3D Series 11.4.
High Speed Pan/Tilt System Safety | en 1 Safety 1.1 Important safety instructions 5 Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating instructions before operating the unit. 1. Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions provided with the unit. Generally, using a dry cloth for cleaning is sufficient, but a moist fluff-free cloth or leather shammy may also be used.
en | Safety High Speed Pan/Tilt System 11. Safety check - Safety checks should be performed upon completion of service or repairs to the unit to ensure proper operating condition. 12. Installation - Install in accordance with the manufacturer's instructions and in accordance with applicable local codes. 13. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer.
High Speed Pan/Tilt System 1.3 Safety | en 7 Important notices Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit may fall, causing serious injury and/or serious damage to the unit. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer. When a cart is used, use caution and care when moving the cart/apparatus combination to avoid injury from tip-over.
en | Safety High Speed Pan/Tilt System redundant recording systems, and a procedure to back up all analog and digital information. Copyright This user guide is the intellectual property of Bosch Security Systems and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. NOTICE! i F01U.073.990 | Version 1.0 | 2007.
High Speed Pan/Tilt System 2 Unpacking | en 9 Unpacking This equipment should be unpacked and handled with care. If an item appears to have been damaged in shipment, notify the shipper immediately. Verify that all the parts listed in Section 2.1 Parts List are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. The original packing carton is the safest container in which to transport the unit and must be used if returning the unit for service.
2.3 en | Description High Speed Pan/Tilt System Safety Rules To ensure safety, the following warnings are specified: – – The device must be installed and maintained by skilled technical personnel. Connect the device to a power source corresponding to the indications given on the marking label. – The device has been designed for permanent installation in a building or other suitable structure.
High Speed Pan/Tilt System 4 Installing the High Speed Pan/Tilt | en 11 Installing the High Speed Pan/Tilt This chapter outlines the procedures needed to install the High Speed Pan/Tilt. Installation should only be done by qualified service personnel in conformance to all local codes. i 4.1 NOTICE! The High Speed Pan/Tilt unit cannot be mounted upside down! This will stress bearings and mechanical components; no liabilities are accepted and all warranties are void.
en | Installing the High Speed Pan/Tilt High Speed Pan/Tilt System CAUTION! Medium Risk: Be sure to use appropriately strong and load bearing bolts and other fixing materials when installing any UPH mountings to any surface. When the MTC-WUPH Wall Mount is fixed to a wall, each fixing dowel must be able to support a traction load of 300daN or more. It is necessary to use 8 mm (0.315 in.) diameter bolts with appropriate length. ! 3.
High Speed Pan/Tilt System Installing the High Speed Pan/Tilt | en 8. 13 Fasten the base to the wall or pole mount with the supplied screws and washers (use a calibrated torque wrench setting of 2.1 Nm). 1 6 1 7 2 2 3 3 4 4 5 5 Fig. 4.3 Wiring the Device Reference # Description 1 Base 2 Gasket 3 Screw Ring 4 Washer 5 Screw 6 Bracket 7 Support Fig. 4.4 9. Preparing the Cables for Wiring Cut the cables to approximately 152.4 mm (6 in) (see Figure 4.4).
en | Installing the High Speed Pan/Tilt High Speed Pan/Tilt System 11. Make a group with all signal cables and fix them with the tie thread. Figure 4.5 indicates a proper cable connection. Fig. 4.5 4.2 Tie Threads used to Group and Secure Signal Cables Wiring the Video Cable To wire the video cable, proceed as follows: 1. Strip the video cable with a pair of wire strippers. 2. Cut the length of the center conductor and the braid to approximatley 30 mm (1.2 in.). 3.
High Speed Pan/Tilt System 4.3 Installing the High Speed Pan/Tilt | en 15 Connecting the Power Supply The base with power supply box is available in two (2) power supply voltages (24 VAC or 230 VAC). Before proceeding with the installation, check the identification label of the product to verify that the device coincides with the power supply requirements. CAUTION! ! When connecting the base, make sure the power supply is disconnected and that the disconnecting switch is open.
en | Installing the High Speed Pan/Tilt High Speed Pan/Tilt System Note: The power cable must be double insulated, i.e. each separate cable is individually insulated, then contained in an outer insulated cover. The cable type must be chosen in accordance with local and national wiring rules; recommended cable type H05RN-F 1mm2 both for 24 VAC and 230 VAC installations. CAUTION! The device must be wired by skilled technical personnel.
High Speed Pan/Tilt System 5 Connecting the Washer Pump (optional) | en 17 Connecting the Washer Pump (optional) The device must be wired by skilled technical personnel. Never make any changes or connections that are not described in this handbook. Failure to follow the instructions indicated in this manual may result in system or safety hazards, thus invalidating the guarantee. ! The High Speed Pan/Tilt System may have an optional washer pump.
en | Connecting the Washer Pump (optional) High Speed Pan/Tilt System 2. Insert the cables inside the mount so they protrude approximately 0.5 m (19.7 in.). 3. Insert the cable into the cable glands and, keeping the base at about 20 cm (7.9 in.) from 4. Set the base on the mount, aiding the cables to achieve the correct position inside. 5. Attach the base to the mount using the supplied screws. the support, lock the cable glands. 6.
High Speed Pan/Tilt System Connecting the Washer Pump (optional) | en 19 1 Fig. 5.3 Calibrating the Nozzle The diagram below refers to the 19-pin connector on the base board of the pan/tilt. Fig. 5.4 Bosch Security Systems Connecting the Washer Pump Instruction Manual F01U.073.990 | Version 1.0 | 2007.
en | Connecting the Washer Pump (optional) Reference High Speed Pan/Tilt System Description AL1 Alarm input, voltage-controlled (10-35 V), to monitor the presence of water in the tank. For devices with level sensors (HAC-WAS05-50, HAC-WAS30-50), closure of the contact, if enabled, generates an on-screen alarm (see Figure 11.3.5 to configure the alarm). O1-C1 Clean contact for starting the water pump. K1 Power relay (external), able to start the water pump.
High Speed Pan/Tilt System 5.1 Connecting the Washer Pump (optional) | en 21 Connecting the Peripherals The base has a 19-pin connector for which the following connections are illustrated: Fig. 5.
6 en | Attaching the Top Unit High Speed Pan/Tilt System Attaching the Top Unit Each time the top unit requires re-assembling, the screw seals should be replaced (use a calibrated torque wrench setting of 2.1 Nm) to ensure the appliance remains water tight. Inside the bottom cover there is a small bag containing mineral salts that are used to prevent moisture formation in the base and near the connector boards.
High Speed Pan/Tilt System Attaching the Top Unit | en Fig. 6.2 5. 6. 23 Aligning the Tabs Push down to snap into place. Attach the top unit to the base using the supplied attachment screws and corresponding seals (see Figure 6.3). 7. Bosch Security Systems Tighten the base with a 4 mm Allen wrench. Instruction Manual F01U.073.990 | Version 1.0 | 2007.
en | Attaching the Top Unit High Speed Pan/Tilt System Fig. 6.3 Attaching the Top Unit Reference # Description 1 Configuration Window 2 Base 3 Screw 4 Screw Seal 5 Gasket CAUTION! Medium Risk: Place safety label near unit that warns of moving parts. ! Fig. 6.4 Safety Label F01U.073.990 | Version 1.0 | 2007.
High Speed Pan/Tilt System 7 Configuring the Device | en 25 Configuring the Device Before powering the High Speed Pan/Tilt, it must be properly configured. To configure the DIP switches inside the configuration window, proceed as follows: 1. Open the configuration window by unscrewing the screws with a 3 mm Allen wrench. See Figure 6.3 for the location of the configuration window. 2. Verify that the position of the DIP switches are the same as in Figure 7.1.
7.2 en | Configuring the Device High Speed Pan/Tilt System Protocol Switches There is no need to set any particular protocol, the UPH is auto-sensing. The protocols supported are: Protocol Pelco D Biphase and Bilinx Baud Rate 2400 (8N 1) Menu setup (OSD) Preset 95 Auto AUX-On 200 Table 7.2 Supported Protocols 7.3 Setting the Address The UPH address can have a setting from 1 to 255. Binary code is used to select the address, using the 8 DIP switches on the far right.
High Speed Pan/Tilt System 7.3.1 27 Address Combinations Fig. 7.2 Bosch Security Systems Configuring the Device | en Address table Instruction Manual F01U.073.990 | Version 1.0 | 2007.
7.4 en | Configuring the Device High Speed Pan/Tilt System Connections Please take note of the particular UPH model that you have installed. All three versions, UPHZ, UPH-2D, and UPH-3D Series, support Bilinx and Biphase telemetry control, i.e.: PTZ. The camera menu setup of UPH-Z Series is done via the OSD, i.e.: AUX ON - 200 - Enter. The camera menu setup of UPH-2D and UPH-3D Series is done via two different AUX commands, i.e.
High Speed Pan/Tilt System Configuring the Device | en 29 Intuikeyboard BOSCH Prod Mon Shot Clr 1 2 3 4 5 6 7 8 9 Divar 0 RS-485 Biphase Divar Bilinx/Video UPH Series: unitized pan/tilt head Intuikeyboard BOSCH Prod Mon Shot Clr 1 2 3 4 5 6 7 8 9 Allegiant 0 RS-485 Biphase Bilinx/Video Intuikeyboard Intuikeyboard Allegiant + BOSCH BOSCH ProdProd Mon Mon ShotShot Clr Clr 1 1 2 2 3 3 LTC 8016 Divar - Bilinx 4 4 5 5 6 6 7 7 8 8 9 9 0 0 RS-485 RS485 - orDivar
en | Configuring the Device High Speed Pan/Tilt System Bilinx/Video DiBos 8 Biphase DiBos 8 Video UPH Series: unitized pan/tilt head Video DiBos 8 LTC 8786 RS-232 Biphase Vidos, IE, DiBos 8, Bosch VMS or equivalent RS485-2 LAN Ethernet VIPX1 Ethernet Video Fig. 7.3 Connection Diagrams F01U.073.990 | Version 1.0 | 2007.
High Speed Pan/Tilt System 8 Switching On and Off | en 31 Switching On and Off Systems in the UPH line are switched on by simply connecting the power supply, and switched off by disconnecting the power supply. When the UPH is powered up in an environment below 0 °C, the device checks it’s internal components to make sure that they are warm enough to start without damage.
en | On-screen Display (OSD) High Speed Pan/Tilt System NOTICE! High temperatures can also have a negative effect on camera image. If the ambient (outside) air temperature exceeds 40 deg Celsius (104 deg Fahrenheit), the HSPT will continue to operate, however some unusual effects may appear on the video signal. These are blemishes that appear as very small white dots on the video picture.
High Speed Pan/Tilt System Moving Around the Menus | en MAIN MENU 1 - LANGUAGE 2 - DISPLAY SETUP 3 - MOTION PARAMETERS 4 - CAMERA PARAMETERS 5 - LOAD DEFAULT CONFIG 6 - SETUP INFO Fig. 10.1 33 Accessing the Main Menu - AUX On 200 MODE ALC ENHANCE COLOR BLC VMD MODE ID DEFAULTS 2 OFF OSD TRAFFIC EXIT Fig. 10.2 Accessing the DinionXF camera Setup Menu - AUX On 46 (screen may differ depending on the camera type) 10.
en | Configuring the System 10.2 High Speed Pan/Tilt System Changing the Settings To change a setting, proceed as follows: 1. AUX ON - 200 - Enter to enable the OSD. 2. Move the cursor to the parameter to be changed. 3. Press the confirmation (Focus) button. The field starts flashing, indicating that it is in change mode. Operating the joystick (up and down) shows the alternative choices. 4.
High Speed Pan/Tilt System 11.1 Configuring the System | en 35 Language Menu This menu is used to select and set the desired language. The default setting is English. LANGUAGE MENU 1 - ITALIANO 2 - ENGLISH 3 - FRANCAIS 4 - DEUTSCH Fig. 11.2 OK Language Menu with English Selected. OK is displayed next to your choice, and the language is changed immediately. 11.2 Display Setup Menu The Display Setup menu is used to define settings for the information that is permanently displayed on the screen.
en | Configuring the System High Speed Pan/Tilt System Feature Description Default Options PAN/TILT POSITION Shows the current position of the device (in degrees) with reference to the home position. YES YES, NO PRESET TITLE Enables or disables the preset title on the display. YES YES, NO PRESET POSITION Enables or disables the preset number reached YES on the display. YES, NO TILT LIMIT TITLE Enables or disables displaying if the tilt limit is YES reached.
High Speed Pan/Tilt System 11.2.1 Configuring the System | en 37 Area Parameters Menu The Area Parameters menu enables the user to show a message on the screen, depending on the horizontal position reached by the device; this is sometimes known as sector information. From this menu, it is possible to enter two (2) lower menus that are used to set the text for each area, and the start and end positions (in degrees) of these areas.
en | Configuring the System High Speed Pan/Tilt System +/-180° 0° 120° 80° Fig. 11.5 Setting the Area Position Values 11.2.2 Changing the Edit Text Menu To change the text within the Edit Text menu, proceed as follows: 1. Upon accessing the Edit Text menu, select String Edit. The first field flashes a "v", indicating it is in Edit mode (see Figure 11.6). 2. Press the Focus button. The cursor flashes at the bottom of the screen, corresponding to the groups of alpha/numeric characters.
High Speed Pan/Tilt System Configuring the System | en 39 The character being edited flashes and the joystick (up and down) can be used to change it. After making the change, confirm and continue to edit the text, or else exit with the Iris button. EDIT TEXT MENU v____________________ > 1ABC 5MNO 9YZ Fig. 11.6 2DEF 6PQR 0()x 3GHI 4JKL 7STU 8VWX +,-. Edit Text Menu Offset Pan By default, the offset pan is +0.00.
en | Configuring the System 11.3 High Speed Pan/Tilt System Motion Parameters Menu The Motion Parameters menu is used to control the speed, limits, preset/patrol/autopan, wiper-washer, and the alarm settings of the UPH. MOTION PARAMETERS MENU 1 - SPEEDS 2 3 4 5 - LIMITS PRESET/PATROL/AUTOPAN WIPER-WASHER ALARMS Fig. 11.8 Motion Parameters Menu 11.3.1 Speed Menu The Speed menu is used to control the pan and tilt movement of the UPH in manual control mode using the joystick.
High Speed Pan/Tilt System Configuring the System | en Feature Description Default 41 Options PAN SPEED 1 Correspondance between joystick 1.0 0.1-100.0 PAN SPEED 2 position and UPHspeed. Joystick 2.0 0.1-100.0 PAN SPEED 3 positions have been divided into 7 5.0 0.1-100.0 PAN SPEED 4 levels for both axis (pan & tilt); 10.0 0.1-100.0 PAN SPEED 5 each level corresponds to a 20.0 0.1-100.0 PAN SPEED 6 defined speed which can be modi- 30.0 0.1-100.0 PAN SPEED 7 fied by the user. 40.
en | Configuring the System 11.3.2 High Speed Pan/Tilt System Limits The Limits menu sets the movement limits for the UPH. These limits apply to all presets, autopan and patrols, including manual operation of the UPH using the joystick. After the limits are set in the OSD and the UPH moves into the "limited pan and tilt zone", it will not move outside of those limits until they are altered in the OSD or the UPH is reset. On reset, the UPH returns to within the limited pan and tilt zone.
High Speed Pan/Tilt System 11.3.3 Configuring the System | en 43 Preset/Patrol/Autopan The Preset/Patrol/Autopan menu sets the movement limits related to the UPH. MOTION PARAMETERS MENU 1 - PRESET 2 3 4 5 - SPECIAL PRESET PARAM. HOME POSITION PATROL AUTOPAN 8 - MOTIONS RECALL Fig. 11.11 Preset/Patrol/Autopan Menu Feature Description PRESET A pre-selected and stored combination of pan, tilt and zoom positions that allow a set view to be recalled.
en | Configuring the System High Speed Pan/Tilt System Preset Menu The Preset menu displays and allows changes to all parameters for the available preset positions in the UPH. Use the up and down function of the joystick to move between the presets in units, i.e.: PRST 01 to PRST 02 to PRST 03. Use the left and right function of the joystick to move between the presets in tens, i.e.: PRST 01 to PRST 11 to PRST 21.
High Speed Pan/Tilt System Configuring the System | en 45 Special Preset Parameters The Special Preset Parameters menu can be used to make parameter settings. Increase the default value to increase the speed between presets or the scan speed. SPECIAL PRESET PARAMETER MENU 1 - PRESET SPEED REF. 2 - SCAN SPEED 3 - TILT SPEED REDUCTION 6 - FIRST DWELL TIME 7 - FORCE PRST DW.TIME 8 - FORCE PRST SPEED Feature Bosch Security Systems : 20.0 : 20.
en | Configuring the System High Speed Pan/Tilt System Home Position The Home Position menu is one of the 250 presets which can be defined as a preset position. Please note that through the normal Set Shot Command, only 99 presets can be stored. Use this menu for presets 100 to 250. HOME MENU 1 - HOME POSITION : 2 - REACHED SPEED : 00001 20.0 Fig. 11.13 Home Menu Feature Description Default HOME POSITION Preset position associated with the home function.
High Speed Pan/Tilt System Configuring the System | en 47 Patrol (loading of preset positions) The Patrol menu is a defined path from preset to preset. This can be from two (2) presets up to 250. For example, the random option allows various presets such as preset 4, then preset 1, then preset 8, then preset 3. PATROL MENU 1 - START POSITION : 2 - END POSITION : 3 - FIRST PRST SPEED : 4 - RANDOM : Fig. 11.14 Patrol Menu Feature Bosch Security Systems 00001 00250 20.
en | Configuring the System High Speed Pan/Tilt System Autopan The Autopan menu is used to indicate preset position settings. AUTOPAN MENU 1 - START POSITION : 2 3 4 5 - END POSITION REACH SPEED FORWARD SPEED REVERSE SPEED 00002 00001 10.0 10.0 20.0 : : : : Fig. 11.15 Autopan Menu Feature Description Default Options START POSITION First preset position. 00002 00001 00250 END POSITION Second preset position. 00001 00001 00250 REACH POSITION Preset position to be reached. 010.0 .
High Speed Pan/Tilt System 11.3.4 Configuring the System | en 49 Wiper-Washer Select UPH Pan/Tilt models have a wiper option used to operate an (external) pump for cleaning the glass. The spray for cleaning the glass is on the outside of the pan/tilt (see Figure 11.16). For cleaning, the UPH must be positioned with the glass facing the spray. Start the pump for the glass cleaning liquid and then start the wiper.
en | Configuring the System 11.3.5 High Speed Pan/Tilt System Alarms The Alarms menu is used to set up the action and duration of the alarm when it is activated.
High Speed Pan/Tilt System 11.4.1 Configuring the System | en 51 UPH-2D and UPH-3D Series (DinionXF Cameras) MODULE PARAMETERS MODULE PARAMETER 1 - ZOOM/FOCUS/IRIS 2 - AREAS MASKING 1 - ENABLED ZOOM : YES : 003 : YES : 003 : YES : 003 : 8 - DEFAULT VALUES LOADING 2 3 4 5 6 MASKING MANAGEMENT MENU 1 - MASK TEXT 2 - MASK POSITION - WINDOW ZOOM ENABLED FOCUS WINDOW FOCUS ENABLED IRIS WINDOW IRIS AREAS MASKING TEXT MENU 1 - MASK. 1 2 - MASK. 2 3 - MASK. 3 4 - MASK. 4 5 - MASK.
en | Configuring the System 11.4.2 High Speed Pan/Tilt System UPH-Z Series (camera module) 1 2 3 4 5 - 7- LENS MODULE PARAMETERS ZOOM FOCUS AUT EXPOSURE INFRARED DYNAMIC MASKING VARIOUS Fig. 11.20 Camera Module Parameters Menu Feature Description ZOOM Electronically or optically enlarging or reducing the size of an image. FOCUS To adjust a lens so that it produces the sharpest visual image. AUT EXPOSURE To select the exposure mode: AUTOMATIC or MANUAL.
High Speed Pan/Tilt System Configuring the System | en 53 Focus Parameters Menu The Focus Parameters menu is used to enable focus settings. 1 2 3 4 5 - FOCUS PARAMETERS MANUAL SPEED AUTOFOCUS TYPE SENSIBILITY AUTOFOCUS FOCUS MIN. LIMIT Fig. 11.22 Focus Parameters Menu Feature Bosch Security Systems MENU 005 TRIG HIGH YES 150 Description Default MANUAL SPEED The speed can take values between zero (0) minimum speed and seven (7) maximum speed.
en | Configuring the System High Speed Pan/Tilt System Auto Exposure Parameters Menu The Auto Exposure Parameters menu is used to control the iris of the UPH-Z Series. In Automatic mode the iris of the camera/lens combination automatically reacts to light level changes. In Manual mode the user has full control of the iris. 1- AE PARAMETERS MODE: AUTOMATIC Fig. 11.
High Speed Pan/Tilt System Configuring the System | en 55 It is possible to set up a maximum of eight (8) simultaneous masks. If the device is used at the maximum speed, video signal update times become critical and it is necessary to create masks that are larger than the object to be hidden to be sure it will not be seen. Fig. 11.25 Dynamic Masking PARAMETERS MODE - MASKING 1 - MASK NR 001 2 - MASK CHANGING 3 - POSITION RECALL 4 - CHANGING COLOR YELLOW 5 - MASK COLOR BLUE 001 1..................
en | Configuring the System 11.5 High Speed Pan/Tilt System Creating a New Dynamic Mask Select "Mask Changing" and an 8 x 6 grid is displayed on the screen. In the top right corner is the Mask Number, and in the bottom left corner is the text "PTZ Mode: Masking". Then proceed as follows: Press Set Shot - 1 - Enter to change from masking mode to move camera mode.
High Speed Pan/Tilt System Configuring the System | en Parameters Mode - Various 1 - BACK LIGHT COMPENSAT 2 - IMAGE STABILIZATION Fig. 11.28 NO NO Parameters Mode - Various Feature Bosch Security Systems 57 Description Default Options BACK LIGHT COMPEN- Reduces negative effects from NO SAT bight backlights. This feature is scene dependent, therefore, it is recommended to test this feature on site.
en | Configuring the System 11.6 High Speed Pan/Tilt System Load Default Configuration The Load Default menu is used to load the default settings. DEFAULT VALUES MENU 1 - LOAD DEF. VALUES? 2 - DELETE ALL PRST? YES NO ATTENTION!!! RELOAD ALL SETTINGS EXCEPT FOR PRESETS Fig. 11.29 Load Default Menu DEFAULT VALUES MENU 1 - LOAD DEF. VALUES? 2 - DELETE ALL PRST? NO YES ATTENTION!!! CLEARS ONLY THE PRESETS Fig. 11.30 Clear All Presets 11.
High Speed Pan/Tilt System 12 Maintenance | en 59 Maintenance UPH pan/tilt devices require no particular maintenance. 12.1 Cleaning To clean the device, use neutral detergent and a non-abrasive cloth. 12.2 Replacing the Fuses There are two (2) preset fuses on the connection board. Sizes are related to the power supply voltage, as shown in Table 12.1.. Fig. 12.1 Fuses on the Connection Board Voltage Fuse F2 24 VAC 50/60 Hz T 4A L 250 V T 6.
13 en | Troubleshooting High Speed Pan/Tilt System Troubleshooting Problem Possible Cause The device is switched off and shows no signs of life. Solution Incorrect wiring, fuses Make sure all the connections are corblown. rect, check the continuity of the fuses and, if there is a failure, replace them according to the values shown in the table. NOTE: if the fuses blow repeatedly, contact the authorized service centre.
High Speed Pan/Tilt System 13.1 Troubleshooting | en 61 Dimensions and Range of Movement 258 (10.16) 584 (22.99) 514 (20.24) Bosch Security Systems Instruction Manual F01U.073.990 | Version 1.0 | 2007.
en | Troubleshooting High Speed Pan/Tilt System 514 (20.24) -40º º 90 73 (2.87) R 38 5 (1 5. 16 374 (14.72) 724 (28.50) R35 (13. 0 78) ) Fig. 13.1 Dimensions and Range of Movement F01U.073.990 | Version 1.0 | 2007.
High Speed Pan/Tilt System 14 Technical Specifications | en 63 Technical Specifications Horizontal movement (Pan) Continuous rotation Vertical movement (Tilt) +90 ° / -40 ° Horizontal pan speed Variable from 0.1 °/s to 100 °/s Vertical tilt speed Variable from 0.1 °/s to 40 °/s Operating temperature UPH-Z Series: -20 °C to +40 °C UPH-2D Series: -20 °C to +40 °C UHP-3D Series: -20 °C to +40 °C Power supply 230 VAC 50/60 Hz 24 VAC 50/60 Hz Current consumption 0.5 A (230 VAC) 4.
Bosch Security Systems Robert-Koch-Straße 100 D-85521 Ottobrunn Germany www.boschsecuritysystems.