22 en | Installation LECTUS select
2021-01 | 01 | F.01U.389.837
Installation manual
Bosch Security Systems B.V.
Phg_crypt protocol
Address 1 2 3 4 5 6 7 8
S1 ON - ON - ON - ON -
S2 - ON ON - - ON ON -
S3 - - - ON ON ON ON -
S4 - - - - - - - ON
S5 Adjustment of the baud rate: ON: 19200, OFF 9600
S6 Bus terminator resistor (default - OFF)
i
Notice!
For the phg_crypt protocol, address 0 is also valid (switches S1 to S4 set to OFF).
3.5.2 Connecting and mounting the reader module
1. Insert the wired connection terminal on the reader module.
2. Place the reader module flat on the wall bracket. Push the connection cable with the
reader module back into the flush-mounted box.
3. Push the attached reader module down until the reader module clicks into place on the
wall bracket.
4. After it has successfully clicked into place, slide the locking bar into the reader module
until it also clicks into place.
– NOTE: A clear click can be heard each time it clicks into place.
2
1
2