Owner Manual

47
RIVET-SPAN
®
Borroughs Corporation – Proudly Manufactured in the U.S.A.
BEAM CAPACITIES
POST CAPACITIES
1.875" x 1.875"
1.57" x 1.57"
ANGLE
POST
HD ANGLE
POST
Calculated Post Capacities
Pounds Allowable Load Per Post
Maximum Beam
Spacing
Angle Post
Heavy-Duty
Angle Post
48" 1,170 1,750
42" 1,315 1,960
36" 1,460 2,180
30" 1,605 2,390
24" 1,750 2,610
18" 1,896 2,830
12" 2,040 3,050
Maximum beam spacing is determined as the distance between left-to-right beams
or front-to-back beams, whichever is greater.
Capacities are for vertical loads only where seismic forces are not a factor.
Beam
Length
Single Rivet
Beam
Double Rivet
Low
Profile Beam
Double Rivet
Z Beam
Double Rivet
Z Beam
w⁄o Tie
Double Rivet
Angle Beam
Double Rivet
Angle Beam
w⁄Support
Tie
Double Rivet
Channel Beam
w⁄Support Tie
36" 350 450
1,400 1,400
42" 260 430
1,350 1,000
48" 240 400
1,300 1,600 730 1,700
60"
800 950 680 1,300 2,250
69"
600 900 460 1,100 1,900
72"
600 900 450 1,050 1,700
96"
240 650 1,300
(1) support tie per level except 96" which has (2) support ties.
The longest pair of beams at a given level determines the capacity for the entire level.
Capacities are for steel beams only and do not reflect the capacity of the decking material.