Operation Manual

98
2 4 E
1
L1 N E
3 5
220 / 230 VAC
240 VAC
Connection Diagrams
Caution: You must comply with local codes and ordinances. Always have your range cooker installed by
a qualifi ed technician. Boretti is not liable for malfunctions or damage as a result of incorrect instal-
lation.
2 4 E
1 3 5
220 / 230 VAC 2N2
240 VAC 2N2
L1 L2 N1 N2 E
2 4 E
1 3 5
380 / 400 VAC 3N 415 VAC 3N
220 / 230 VAC 3N 240 VAC 3N
L1 L2 L3
N
E
2 4 E
1 3 5
220 / 230 VAC 3
240 VAC 3
L1 L2 L3 E
2 4 E
1 3 5
380 / 400 VAC 2N
415 VAC 2N
L1 L2 N E
Power and Values
NL
Burner Semi-rapid Rapid Wok Fish Coup de Feu Gas Oven 60 Gas Oven 90
Nominal Capacity (kW) 1,80 2,60 4,30 3,10 2,60 2,50 3,50
Minimum fl ow rate (kW) 0,60 0,62 1,70 1,00 0,62 0,90 1,30
Diameter (spray nozzle)
Semi-rapid Rapid Wok Fish Coup de Feu Gas Oven 60 Gas Oven 90
G25 - 25 mbar 0,97 1,23 1,55 1,35 1,23 1,17 1,50
G30 / G31 - 30 mbar 0,62 0,78 1,00 0,82 0,78 0,75 0,90
BE
Burner Semi-rapid Rapid Wok Fish Coup de Feu Gas Oven 60 Gas Oven 90
Nominal Capacity (kW) 1,80 2,60 4,30 3,10 2,60 2,50 3,50
Minimum fl ow rate (kW) 0,60 0,62 1,70 1,00 0,62 0,90 1,30
Diameter (spray nozzle)
Semi-rapid Rapid Wok Fish Coup de Feu Gas Oven 60 Gas Oven 90
G25 - 25 mbar 0,97 1,17 1,50 1,30 1,17 1,17 1,40
G30 / G31 - 30 mbar -
28...30/37 mbar 0,62 0,78 1,00 0,82 0,78 0,75 0,90
ES
Burner Semi-rapid Rapid Wok Fish Coup de Feu Gas Oven 60 Gas Oven 90
Nominal Capacity (kW) 1,80 2,60 4,30 3,10 2,60 2,50 3,50
Minimum fl ow rate (kW) 0,60 0,62 1,70 1,00 0,62 0,90 1,30
Diameter (spray nozzle)
Semi-rapid Rapid Wok Fish Coup de Feu Gas Oven 60 Gas Oven 90
G25 - 25 mbar 0,97 1,17 1,50 1,30 1,17 1,17 1,40
G30 / G31 - 30 mbar -
28...30/37 mbar 0,62 0,78 1,00 0,82 0,78 0,75 0,90