Specification

Technical Evaluation Report (TER)
TER No. 1212-01 Page 6 of 10
Versetta Stone
®
Panelized Stone Veneer
Applications Over Continuous Insulation
Copyright © 2018
Exposure
Category
Wind Speed,
V
ult
(mph)
Mean Roof Height
15'
20'
25'
30'
35'
40'
B
110
29.1
29.1
29.1
29.1
30.6
31.7
115
31.9
31.9
31.9
31.9
33.5
34.8
120
34.7
34.7
34.7
34.7
36.4
37.8
130
40.7
40.7
40.7
40.7
42.7
44.4
140
47.2
47.2
47.2
47.2
49.6
51.4
150
54.2
54.2
54.2
54.2
56.9
59.1
160
61.7
61.7
61.7
61.7
64.8
67.3
180
78.0
78.0
78.0
78.0
81.9
85.0
200
96.3
96.3
96.3
96.3
101.1
105.0
C
110
35.2
37.5
39.3
40.7
42.2
43.4
115
38.6
41.2
43.1
44.7
46.3
47.5
120
42.0
44.8
46.8
48.6
50.3
51.7
130
49.2
52.5
54.9
57.0
59.0
60.6
140
57.1
60.9
63.7
66.1
68.4
70.3
150
65.6
69.9
73.2
75.9
78.6
80.8
160
74.7
79.6
83.3
86.4
89.5
91.9
180
94.4
100.6
105.3
109.2
113.1
116.2
200
116.5
124.2
130.0
134.8
139.6
143.5
D
110
42.8
45.1
46.9
48.3
49.5
50.6
115
46.9
49.4
51.4
53.0
54.2
55.5
120
51.0
53.8
55.9
57.6
59.0
60.4
130
59.8
63.1
65.5
67.6
69.2
70.8
140
69.4
73.2
76.0
78.4
80.2
82.1
150
79.7
84.0
87.3
90.0
92.1
94.3
160
90.7
95.6
99.3
102.4
104.9
107.4
180
114.7
120.9
125.6
129.5
132.6
135.7
200
141.6
149.3
155.0
159.9
163.7
167.6
Table 4: General Wind Pressure Resistance Criteria per ASCE 7-10 for Components & Cladding, Method 1
5.6. Where the application exceeds the limitations set forth herein, design shall be permitted in accordance with
accepted engineering procedures, experience and technical judgment.
6. Installation:
6.1. General
6.1.1. Versetta Stone
®
shall be installed in accordance with the manufacturer's published installation instructions
and this TER. In the event of a conflict between the manufacturer’s installation instructions and this TER,
the more restrictive shall govern.
6.1.2. Installation is subject to the conditions of use set forth in Section 9.
6.1.3. A water-resistive barrier (WRB) is required behind Versetta Stone
®
in accordance with IBC Section
1404.2 and IRC Section 703.2. The WRB may be comprised of a liquid-applied, sheet material or a
continuous insulation product evaluated for use as a WRB with all joints taped per the manufacturer's
installation instructions.
6.1.4. All Versetta Stone
®
vertical joints shall be staggered between courses.