3.1.5. To determine the ability of various fasteners to support the gravity and transverse loads induced by the
products when installed over concrete and masonry construction with the addition of continuous insulation
installed between the framing and the Versetta Stone
®
.
3.2. Use in applications requiring a fire-resistance rating are outside the scope of this evaluation.
3.3. Any code compliance issues not specifically addressed in this section are outside the scope of this evaluation.
4. Product Description and Materials:
4.1. Versetta Stone
®
is a non-structural, fiber-reinforced, cement-based masonry wall cladding that is mechanically
attached to masonry or concrete walls.
4.2. The panels have a simulated stone veneer surface.
4.3. The panels measure 36.4" long x 9.5" tall and 1.8" thick and have tongue-and-groove edges that engage
adjacent panels.
4.3.1. The finished exposure of the panels is 8" x 36".
4.4. A 0.0217"-thick painted G90 galvanized steel nailing flange is molded along the top edge of the panels for
attachment to the substrate.
4.5. The bottom edge and the ends of the panels fit together using tongue-and-groove technology.
4.6. The panels have an installed weight of approximately 8.5 psf (17 lbs. per panel).
4.7. Additionally, the stone veneer panels are supplemented with various accessories (such as starter strips,
bridging, corner pieces, etc.) to aid with installation.
Figure 1: Versetta Stone
®
Panel with Nailing Hem
(across top of panel)
5. Applications:
5.1. Versetta Stone
®
is used as an exterior wall covering in accordance with the applicable sections of IBC Chapter
14 and IRC Section R703 and is installed over concrete and masonry walls capable of supporting the imposed
loads in accordance with IBC Section 1609 and IRC Section R301.2.1, including all required transverse wind
loads.
5.2. Versetta Stone
®
is also used as an exterior wall covering installed over concrete and masonry walls where the
walls are over sheathed with continuous insulation.
5.3. Fasteners for gravity loaded single shear connections for this installation are as shown in Table 1.
5.4. Versetta Stone
®
shall not be installed in areas where the design wind pressure exceeds the capacity of the
cladding and its attachment to resist the load in accordance with Table 2.
5.4.1. See Table 3 for wind pressures associated with V
ult
per ASCE 7-10.
5.4.2. Table 3 is provided as an aid for designers in determining the allowable wind pressures for Versetta
Stone
®
panel installation. Wind speeds are included for both V
ult
and V
asd
.