Measurement Guide
Technical Evaluation Report (TER)
TER No. 1312-03 Page 2 of 9
Versetta Stone
®
Panelized Stone Veneer
Applications Using Continuous Insulation
Over Concrete or Masonry Walls
Copyright © 2018
1.5. Requiring an evaluation report from a specific private company (i.e. ICC-ES, IAPMO, CCMC, DrJ, etc.) can be
viewed as discriminatory and is a violation of international, federal, state, provincial and local anti-trust and free
trade regulations.
1.6. DrJ’s code compliance work:
1.6.1. Conforms to code language adopted into law by individual states and any relevant consensus based
standard such as an ANSI or ASTM standard.
1.6.2. Complies with accepted engineering practice, all professional engineering laws and by providing an
engineer’s seal DrJ takes professional responsibility for its specified scope of work.
2. Applicable Codes and Standards:
1
2.1. 2012, 2015 and 2018 International Building Code (IBC)
2.2. 2012, 2015 and 2018 International Residential Code (IRC)
2.3. AISI S100 – North American Specification for the Design of Cold-Formed Steel Structural Members (S100)
2.4. ASCE/SEI 7 – Minimum Design Loads for Buildings and Other Structures (ASCE 7)
2.5. ASTM C90 – Standard Specification for Loadbearing Concrete Masonry Units
2.6. ASTM C1185 –Standard Test Method for Sampling and Testing Non-Asbestos Fiber-Cement Flat Sheet,
Roofing and Siding Shingles, and Clapboards
2.7. ASTM C1186 – Standard Specification for Flat Non-Asbestos Fiber-Cement Sheets
2.8. ASTM D3679 – Annex 1 Standard Specification for Rigid Poly Vinyl Chloride (PVC) Siding Pressure
Equalization Testing
2.9. ASTM D5206 – Standard Test Method for Windload Resistance of Rigid Poly Vinyl Chloride (PVC) Siding,
Procedure B
2.10. ASTM E84 – Standard Test Method for Surface Burning Characteristics of Building Materials
2.11. ASTM E2273 – Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish
Systems (EIFS) Clad Wall Assemblies
2.12. AWC NDS – National Design Specification for Wood Construction (NDS)
2.13. AWC TR12 – General Dowel Equations for Calculating Lateral Connection Values (TR-12)
2.14. SBCA FS-100 – Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing
Used in Exterior Wall Covering Assemblies
3. Performance Evaluation:
3.1. Versetta Stone
®
was evaluated:
3.1.1. For use as an exterior wall covering on new or existing concrete or masonry walls in accordance with IBC
Section 1403 and IRC Section R703.
3.1.2. For use as a weather-resistant covering in accordance with IBC Section 1403.2 and IRC Section
R703.1.1.
3.1.3. To determine the ability of the product to resist wind loads in accordance with IBC Section 1609 and IRC
Section R703.1.2.
3.1.4. For use as an exterior finish over concrete or masonry walls with the addition of continuous insulation
installed between the concrete or masonry walls and the Versetta Stone
®
.
3.1.4.1. Foam sheathing shall have a minimum compressive strength of 15 psi in accordance with ASTM
C578 or ASTM C1289 and be qualified for wind pressure resistance in accordance with ANSI/SBCA
FS 100.
1
Unless otherwise noted, all references in this code compliant technical evaluation report (TER) are from the 2018 version of the codes and the standards referenced therein, including,
but not limited to, ASCE 7, SDPWS and WFCM. This product also complies with the 2000-2015 versions of the IBC and IRC and the standards referenced therein. As required by law,
where this TER is not approved, the building official shall respond in writing, stating the reasons this TER was not approved. For variations in state and local codes, if any see Section 8.