Measurement Guide

Technical Evaluation Report (TER)
TER No. 1312-03 Page 4 of 9
Versetta Stone
®
Panelized Stone Veneer
Applications Using Continuous Insulation
Over Concrete or Masonry Walls
Copyright © 2018
5.4.3. Design in accordance with generally accepted engineering practice may be used as an alternative to
Section 5.3.
5.5. For additional information or use in other applications, consult the manufacturer’s installation instructions.
Material
Fastener
Fastener
Diameter (in.)
Minimum
Fastener
Penetration
Thickness of Continuous Insulation (in.)
0"
0.5"
1.0"
1.5"
2.0"
2.5"
3.0"
3.5"
4"
Concrete
(minimum 2,500 psi)
3
/
16
" Tapcon
0.1875"
1.5"
x
x
x
x
x
x
x
1
/
4
" Tapcon
0.25"
1.5"
x
x
x
x
x
x
x
x
x
Hilti X-C
0.138"
0.75"
x
x
x
x
Hilti X-U
0.157"
0.75"
x
x
x
x
x
x
Hilti X-C
0.138"
1"
x
x
x
x
x
Hilti X-U
0.157"
1"
x
x
x
x
x
x
x
Masonry
(medium/normal
hollow CMU per
ASTM C90)
3
/
16
" Tapcon
0.1875"
1"
x
x
x
x
x
x
x
1
/
4
" Tapcon
0.25"
1"
x
x
x
x
x
x
x
x
x
Masonry
(lightweight hollow
CMU per ASTM
C90)
Masonry Nail
0.148”
1"
x
x
x
x
x
3
/
16
" Tapcon
0.1875"
1"
x
x
x
x
x
1
/
4
" Tapcon
0.25"
1"
x
x
x
x
x
x
x
x
x
Hilti X-C
0.138"
1"
x
x
Hilti X-U
0.157"
1"
x
x
x
x
1. Table values are based on the manufacturer’s published fastener properties. The methodology for reducing the fastener capacities to account for the insulation are based
on the NDS allowable lateral loads for fasteners as modified by AWC TR12 for use with a gap parameter for gravity load only (i.e., fasteners sized to support weight of
cladding, while cantilevered from framing a distance equal to the foam sheathing thickness).
2. Maximum thickness of continuous insulation shall include any rain screen material, sheathing that does not serve as a nail base, and airspace between the cladding and the
continuous insulation, where present.
3. Each panel shall contain a minimum of three (3) fasteners and penetrate the concrete or masonry wall as identified above.
4. Where a substrate other than nailable sheathing is used, its thickness shall be added to the continuous insulation thickness for the purpose of determining the fastener size.
5. Fasteners shall have the following minimum head diameter: Masonry nails, 0.312"; Hilti fasteners, 0.322"; Tapcon fasteners, 0.325".
6. Tools used for driving pneumatic or powder actuated fasteners shall be adjusted to avoid over driving the fasteners and damaging the panel.
Table 1: Fastener Requirements to Support Versetta Stone
®
Installation Over Continuous Insulation
in Concrete or Masonry Construction