Installation
www.bora.com
5.9  Basic configuration 
When installation is complete, you must carry out the basic 
settings (these settings can be changed at any time later on).
 i
You can see precise instructions on the basic 
configuration and all necessary information in the 
Configuration menu chapter of the operating instructions.
XX
Follow the instructions on the basic configuration (see 
Operating instructions – “Configuration menu” chapter).
5.10  Initial operation
 i
You will find detailed information on operating the BORA 
Professional 3.0 system in the operating instructions (see 
“Functions and operation” chapter).
XX
Ensure that all appliances are connected correctly and 
connected to the power supply (fused) prior to initial 
operation.
XO
Exception: During initial operation, the kitchen fitter may use 
a temporary power supply for the control unit in order to carry 
out the basic configuration (e.g. using the site power supply 
during the building phase). 
XO
The settings made are saved and will not be affected when the 
system is disconnected from the mains.
XO
The final mains connection to the appliances may only be set 
up by certified specialists.
5.11  Function test
XX
Carry out a thorough function test on all appliances.
XX
In the event of error messages, see the “Troubleshooting” 
chapter in the operating instructions.
Special information for the Tepan stainless steel grill 
PKT3:
 i
This appliance is intended to be operated on a supply 
network with an impedance Zmax at the transfer point 
(mains connection) of 0.116 ohms maximum. The user 
is to ensure that the appliance is only operated on a 
mains supply network which meets this requirement. If 
necessary, ask the local energy supply company about 
the system impedance.
Connecting the cooktop to the power supply
The power supply cable to be used (already pre-installed) must 
comply with certain, appliance-specific requirements (see table 
“Fuse protection and minimum cross-section”).
 i
A damaged power supply cable must be replaced by 
another suitable power supply cable. This may only be done 
by an authorised member of the After Sales Service team.
Power supply cable requirements and connection diagram
Connection Fuse 
protection
Minimum 
cross-section
Power supply 
cable
1-phase 
connection
1 x 25A 2.5mm²
Type H05V2V2-F 
2-phase 
connection
2 x 16A 2.5mm²
Type H05V2V2-F 
Tab. 5.4  Fuse protection and minimum cross-section
1
L1
2 3
N PE
220 - 240 V~
Fig. 5.24  1-phase connection diagram
1
L1 L2
2
N PE
220 - 240 V~
220 - 240 V~
3
Fig. 5.25  2-phase connection diagram
Connecting the cooktop to the mains
XX
Switch off the main switch/automatic circuit breaker before 
connecting the cooktop.
XX
Secure the main switch/automatic circuit breaker against 
being switched back on without permission.
XX
Make sure the power to the appliance is disconnected.
XX
Only connect the cooktop using a permanent connection to a 
power supply cable.
XX
Check that installation has been carried out correctly.
XX
Switch on the main switch/automatic circuit breaker.
XX
Put the cooktop into operation (see the Operation chapter).
XX
Check that all the functions are working correctly.