User's Manual

EN
17
Installation
www.bora.com
5.4.1 Flush installation
x
A ±2
B ±2
544 ±2
≤ R5
≤ R5
≥ 74
(≥ 70)
516 ±2
≥ 700
Fig. 5.3 Cut-out dimensions for ush installation
7 +0,5
14
10 - 40
Fig. 5.4 Groove dimensions for ush installation
Cut-out dimensions when installing cooktops or cooktops
and the cooktop extractor next to each other:
Cooktops/cooktop extractor A in mm B in mm
1/0 374 346
1/1 485 457
2/1 856 828
3/2 1338 1310
4/2 1709 1681
Tab. 5.2 Cut-out dimensions for ush installation of appliance
combinations
5.3.3 Recirculation when using the cooktop
extractor as a recirculation system
In the case of recirculation systems there must be a
return flow aperture in the kitchen units:
> 500 cm² (per air cleaning box) in combination with
cooktops PKFI11, PKI11, PKIW1, PKC32, PKC3B,
PKCH2 and PKT11
INFO If several extractor systems are operated in
recirculation mode, the return flow aperture
for each air cleaning box must be calculated
correspondingly.
Example:
2 recirculation systems = 2 x (> 500 cm²)
For recirculation, the necessary return flow aperture can
be created using a shortened plinth. A slatted plinth with
at least the minimum opening cross-section can also be
used.
Ensure that the return flow aperture is large enough.
5.4 Cut-out dimensions
INFO All dimensions are shown from the front edge of
the front cover.
Worktop overhang
≥60
(
≥74
)
14x
Fig. 5.2 Worktop overhang
Please note the worktop overhang x when creating the
worktop cut-out. Applicable to flush installation and
surface mounting.