User Manual - 2

EN
33
Installation
www.bora.com
6.13 Sealing the devices
1
Fig. 6.50 Silicone sealant for ush installation
[1] black, heat-resistant silicone sealant
1
Fig. 6.51 Silicone sealant for surface mounting
[1] black, heat-resistant silicone sealant
Once all of the installation work and initial operation is
complete, seal the devices all around with black, heat-
resistant silicone sealant (also between the cooktop
extractor and cooktop) [1].
Make sure that no silicone sealant gets under the
cooktop.
6.14 Handover to user
Once installation is complete:
Explain the main functions to the user.
Explain all safety-related aspects of operation and
handling to the user.
Provide the user with the accessories and the
operating and installation instructions for safe storage.
Operation with/without wall sleeve
In the
C5
menu option, you can select whether the
extraction system is operated with or without the
BORA 3box (UEBF) wall sleeve.
Setting Mode
C50
Operation with wall sleeve
C5 1
Operation without wall sleeve
Tab. 6.12 Operation with or without wall sleeve
Manual operation of cover flap motors
You can open or close the cover flap manually in the
menu option
C6
.
Setting Function
C60
Exit sub-menu
C6 1
Opening the cover flap
C62
Closing the cover flap
Tab. 6.13 Manual operation of cover ap motors
6.12.3 Changing the setting
Turn the knob ring clockwise to increase the value.
Turn the knob ring anticlockwise to decrease the value.
Press the touch surface on the control knob again for
1 second to confirm the new setting. The value is saved
and a beep sounds. The previously selected menu
option is shown again on the control knob display.
6.12.4 Exiting configuration menu
Twist the knob ring until the display shows
C
.
Now press the touch surface on the control knob again
for 1 second to exit the configuration menu.
Twist the knob ring to the 12 o’clock position.
0
appears on the display for 10 seconds. The display
then goes out with a beep.
INFO If no settings are changed in a menu or sub-menu
option for 2 minutes, the configuration menu is
closed automatically.