Installation
www.bora.com
Connections on the cooktop
321
ZONE1 INTERF. COM1 ZONE2
Fig. 5.18 Control knob connection at the rear of the cooktop
[1] Connection of the front cooking zone control knob (zone 1)
[2] Connection of the automatic extraction system
[3] Connection of the rear cooking zone control knob (zone 2)
Standard cooking zone connection
5 4
3
2
1
Fig. 5.19 Standard cooking zone connection
[1] Cooktop
[2] Rear cooking zone (zone 2)
[3] Front cooking zone (zone 1)
[4] Rear cooking zone control knob (zone 1)
[5] Front cooking zone control knob (zone 2)
5.5.3 Installation rotated by 180°
Rotate the cooktop 180°.
For the installation, proceed as described above.
Change the installation direction in the configuration
menu (see Configuration menu).
INFO If installation is rotated by 180°, then the
connections for the control knobs and the
extraction system are at the front.
INFO Cables of sufficient length are provided.
5.5.4 Establishing communication
The appliance components are linked by the ribbon cable
provided.
Create the connection between the cooktop and the
control knobs.
Create the connection between the cooktop and the
cooktop extractor.
Cooking zone connection
INFO According to the default settings, the left control
knob operates the front cooking zone and the
right control knob operates the rear cooking zone.
Connection on the control knob
1
Fig. 5.17 Connection on the rear of the control knob
[1] Connection on the rear of the control knob