Installation Guide

EN
31
Installation
www.bora.com
Preparing connection cables for external 
switching equipment
Use connection cables of the following types and 
manufacturers to connect external switching equipment.
Contact Connection cable
Home In H03VV-F 2x 0.5mm²
Home Out H03VVH2-F 2x 0.75mm²
Tab. 4.6  Connection cable
INFO  The connection cable is only intended for internal 
use in buildings, private households, kitchens or 
offices!
INFO  The overall length of the connection cable for 
external switching equipment must not exceed 
10 m!
 Prepare the connection cable in accordance with the 
prescribed stripping lengths.
5
3
2
1
4
9
25
37
45
Fig. 4.35  Stripping lengths and installation position of the 
connection cable
[1]  Stripped wire end
[2]  Insulated wire
[3]  Jacketed cable
[4]  Strain relief clamp
[5]  Cable feed snap-out element
Please adhere to the maximum stripping length of the 
individual wires of 9 mm on the stripped wire end [1].
Please adhere to the maximum stripping length of the 
outer sheath of 25 mm on the insulated wire [2].
Installing the external switch device
Depending on the type of switch device, connect the 
connection cables to either the Home In or the Home Out 
connection clamp.
 Adhere to the connection diagram when connecting 
Home In and Home Out.
Home
In
Home 
Out
X 311.1
X 311.2
X 312.1
X 312.2
Fig. 4.36  Connection diagram for the external switch contacts
 Connect the cable for the relevant contact to 
the switch contact clamp in accordance with the 
connection diagram.
In order to connect the Home In interface, the installed 
bridge must be removed.
INFO  The Home In contact must be bridged if this is not 
used (bridged on delivery).
INFO  For connections to the Home In connection 
clamp, no ferrules may be used.
1
2
Fig. 4.37  Home Out contacts with strain relief
[1]  Strain relief clamp
[2]  Snap-out element for cable feed
 Clamp the connection cable in the strain relief clamp 
[1] in accordance with the wire cross section used.
 Remove the snap-out element [2] required for the 
cable feed from the plastic housing of the control unit.