User's Manual
EN
29
Installation
www.bora.com
INFO The gas type and pressure may only be changed
by a certified engineer or BORA service
technician. He/she also assumes responsibility
for the proper gas installation and commissioning.
Setting Gas type Gas
pressure
Ø SR burner/
n
ormal burner
Ø R burner/
high-power
burner
C
3
0
G20
G25
20 mbar
20 mbar
104
110
125
131
C
3
1
G20 10 mbar 122 155
C
3
4
G30
G31
29 mbar
37 mbar
69
69
85
85
C
3
5
G30
G31
50 mbar
50 mbar
62
65
78
80
C
3
8
G31 30 mbar 75 92
C
3
9
G30
G31
27.5 mbar
27.5 mbar
75
75
92
92
C
3
A
G20 13 mbar 115 149
C
3
b
G25
G25.3
25 mbar
25 mbar
104
104
131
131
C
3
C
G20 25 mbar 100 119
Tab. 5.13 Setting the gas type and gas pressure
Selecting characteristic curves
Under menu option
C
4
you can select the characteristic
curve.
The characteristic curves regulate the minimum gas
burner power values. The minimum power levels are
adjusted using the characteristic curves. Depending on
the installation situation and the influence of the cooktop
extractor, if necessary, the characteristic curve can be
changed:
C40 enables the fine tuning of the power values, which
can only be adjusted in the best-case scenario. The best-
case scenario is when:
no cooktop extractor is used;
the cooktop, when using the cooktop extractor in
exhaust air mode, is used with sufficient ventilation;
or
the cooktop, when using the cooktop extractor in
recirculation mode, is used with sufficient
ventilation; and
the cooktop extractor has no negative influence on
the gas flame.
C
4
1
is the factory default characteristic curve with
balanced adjustment of the individual power levels.
C
4
2
increases the lower power levels and should only
be used in the event of a negative influence from the
cooktop extractor.
INFO The characteristic curve may only be adjusted by
a certified engineer or BORA service technician.
Setting Characteristic curve
C
4
0
Characteristic curve 1
C
4
1
Characteristic curve 2 Factory setting
C
4
2
Characteristic curve 3
Tab. 5.14 Characteristic curves
INFO The menu option
C
4
sets the minimum bottom
power level at each burner.
Selecting GPU reset
With the menu option
C
5
you can select the reset
function.
The menu option
C
5
can be used in the event of faults
and errors. Furthermore, it can also be used for initial
operation when the gas cooktop does not react (does not
ignite).
INFO The gas type and gas pressure values set remain
unchanged and are not affected by the reset.
Setting
C
5
0
Reset
Tab. 5.15 GPU reset
Availability of the pause function
Once you have confirmed menu option
C
9
, you can
permanently deactivate the pause function.
Setting Pause function available/deactivated
C
9
0
Pause function activated Factory setting
C
9
1
Pause function deactivated
C
9
2
Pause function with power level display activated
Tab. 5.16 Availability of the pause function
5.7.3 Changing the set value
Turn the knob ring clockwise to increase the value.
Turn the knob ring anti-clockwise to reduce the value.
Press the touch surface on the control knob for 1
second to confirm the new value. The value is saved
and a beep is heard. The previously selected menu
option is shown in the control knob display.