Installation
www.bora.com
Connecting the automatic extraction system
2
ZONE1 INTERF. COM1 ZONE2
1
ZONE1 INTERF. COM1 ZONE2
3
Fig. 5.24 Connection of the automatic extraction system
[1] Connection of the automatic extraction system (cooktop
extractor)
[2] Connection of the automatic extraction system (cooktop)
[3] Automatic extraction system cable
Connect the cooktop extractor
[1]
to the cooktop using
the connector provided for the automatic extraction
system
[2]
.
5.5.5 Establishing the power connection
Observe all safety and warning information (see the
Safety chapter).
Observe all national and regional laws and regulations
as well as the supplementary regulations of the local
utility companies.
INFO The power connection may only be established by
certified specialists. The specialist also assumes
responsibility for the proper installation and
commissioning.
The power supply line to be used (pre-assembled) must
be at least type H05VV-F or H05VVH2-F (see table Fuse
protection and minimum cross-section).
Connection Fuse protection Minimum
cross-section
1-phase connection 1 x 16 A
1.5 mm²
Tab. 5.4 Fuse protection and minimum cross-section
If the connection cable has been damaged this must
be replaced. This may only be done by an authorised
member of the After Sales Service team.
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
Make sure the power to the appliance is disconnected.
Only connect the cooktop using a permanent
connection to a power supply cable.
1
L1
2
N PE
220 - 240 V~
Fig. 5.25 Connection diagram 1-phase
Check that installation has been carried out correctly.
Switch on the main switch/automatic circuit breaker.
Put the cooktop into operation (see the Operation
chapter).
Check that all the functions are working correctly.
5.6 Gas installation
The gas connection may only be carried out by an
authorised gas fitter in accordance with applicable legal
and local regulations. Comply with local regulations of the
utility companies.
Country Regulation/guidelines
Germany DVGW TRGI 2018 and DVGW-worksheet G 600
Austria ÖVGW-GK-guidelines
Switzerland SvgW Gas Regulations G1
EKAA guideline 6517
Regulations of the Vereinigung Kantonaler
Feuerversicherungen (VKF)
Netherlands
Belgium France
Regulations of standard NBN D 51-003
Regulations and connection requirements of
the gas supply company (G.D.F.) and electricity
supply company (E.D.F)
Tab. 5.5 Country requirements (information supplied without
liability)
5.6.1 Ventilation
This appliance is not connected to a flue gas evacuation
device. It must be positioned and connected in
accordance with the applicable installation conditions.
Suitable ventilation measures must be adhered to in
particular.
Always ensure sufficient ventilation during operation
(of the appliance).