Specifications Sheet
52
BORA CLASSIC 2.0
246
299
40,5
14
7
25
73
37
487
485
14
15
R3
327
131 240
515
BORA VENTILATION HANDBOOK
Technical data
Supply voltage 220 – 240 V
Frequency 50/60 Hz
Maximum power consumption 5.0 kW
Maximum power rating 20 W
Minimum fuse protection 1 x 0.5 A
Power supply cable length 1,5 m
Dimensions (width x depth x height) 327 x 515 x 73 mm
Weight (incl. accessories/packaging) 10.8 kg
Surface material SCHOTT CERAN
®
Cooktop power levels 1 – 9, P
Size of front cooking zone Ø 240 mm
Size of rear cooking zone Ø 200 mm
Front cooking zone output (power burner) 800–3000 W
Rear cooking zone output (normal burner) 550–2000 W
Size of front pan support 270 x 270 x 25/50 mm
Size of rear pan support 235 x 235 x 25/50 mm
Product description
Compact size
Minimalistic design
Modular system
Sunken gas burners
Variable heat retention function
Automatic reignition
Dishwasher-safe pan supports
automatic heat up function
low pan support height
Demo mode
Scope of delivery
Gas cooktop CKG
2 x cast iron pan supports
Nozzle set G20/20mbar natural gas
Flexible gas connection tube, length 500 mm, 1/2“ external thread
mounting straps
height adjustment plate set
Accessories
BORA gas nozzle set natural gas G20/10 mbar PKGDS2010
BORA gas nozzle set natural gas G20/13 mbar PKGDS2013
BORA gas nozzle set natural gas G20/20 mbar PKGDS2020
BORA gas nozzle set natural gas G25/20 mbar PKGDS2520
BORA gas nozzle set natural gas G20/25 mbar PKGDS2025
BORA gas nozzle set natural gas G25/25 mbar PKGDS2525
BORA gas nozzle set liquid gas G30/G31 28-30/37 mbar PKGDS3028
BORA gas nozzle set liquid gas G30/G31 50 mbar PKGDS3050
BORA burner set PKGBS
BORA pan support small PKGTK
BORA pan support large PKGTG
product- and planning instructions
Ensure sucient air supply below the gas cooktop. Either over the front of
the body (opening cross-section > 50 cm²) or over the plinth area (opening
cross-section > 150 cm²)
Provide a return ow aperture (opening cross-section > 1000 cm² per air
cleaning unit) for recirculation in the plinth area
Please note the local regulations and connection requirements applicable to
gas cooktops
Please take into account the special guidelines regarding the assembly and
use of gas cooktop CKG (see operating and installation instructions)
When operating a gas cooktop with a cooktop extractor, the gas ame can
be affected (depending on the height of the power level on the cooktop
extractor)
The performance characteristics of the gas cooktop (e.g. heating times,
eciency, etc.) are affected by the cooktop extractor. The cooktop extractor
also affects the heat input and distribution
If the gas cooktop is used in a model with two cooktop extractors, it is to be
installed at the side
Minimum requirement for operating gas cooktop CKG: System software
03.00 (or higher)
CKG
BORA Classic gas cooktop
BORA Vertriebs GmbH & Co KG · Innstraße 1 · A-6342 Niederndorf · T +43 (0) 53 73 6 22 50 - 0 · mail@bora.com · www.bora.com