Installation Guide

EN
29
Installation
www.bora.com
4.13.3 Establishing contact between the
operating unit and control unit
1
Fig. 4.38 Socket for the CAT 5e communication cable on the
operating unit
1 2 3 4 5 6
Fig. 4.39 Control unit connections
[1] CAT 5e communication cable socket
[2] Control unit socket for fan 2
[3] Control unit socket for fan 1
[4] Mains cable socket for fan 2
[5] Mains cable socket for fan 1
[6] Mains cable socket with micro fuse
XX
Using the CAT5e communication cable (included in the scope
of delivery) link the connections [1] on the operating unit to
the control unit.
i
The operating unit is controlled by and receives its power
supply via the CAT 5e communication cable.
4.13.4 Connecting fans to the control unit
2
1
Fig. 4.40 Fan connection plug
[1] Fan mains cable connection plug
[2] Fan control cable connection plug
XX
Connect the fan control cable [2] to the control unit.
XX
Connect the fan mains cable [1] to the control unit.
XO
When connecting the fan control cable and mains cable it
does not matter if you use socket 1 or 2 on the control unit.
4.13.1 Establishing contact between the
cooktop extractor and cooktops
XX
Only use the cables supplied in the scope of delivery.
45
1 2 3
Fig. 4.36 Connecting the control cables to the cooktops
[1] Left cooktop
[2] Cooktop extractor
[3] Right cooktop
[4] Right cooktop control cable (R)
[5] Left cooktop control cable (L)
XX
Connect the cooktop extractor control cables to the adjacent
cooktops.
XX
Ensure that each cable is connected to the correct socket.
XO
The right angle connectors of the control cables are labelled L
(left) and R (right).
4.13.2 Fitting split ferrite sleeves
i
The cooktop extractor connection cable must be filtered
with a ferrite sleeve for reasons of electromagnetic
compatibility.
1
2
Fig. 4.37 Fitting split ferrite sleeves
[1] Connection cable
[2] Split ferrite sleeve
XX
Fit the split ferrite sleeve [2] provided in the scope of delivery
to the connection cable [1].