Installation Guide
EN
25
Installation
www.bora.com
Adjusting the installation height (only in the case of
flush installation)
1
2
Fig. 4.26 Cooktop and height adjustment plates
[1] Cooktop
[2] Height adjustment plates
XX
Adapt the cooktop [1] installation height to the level of the
cooktop extractor using the height adjustment plates [2].
i
When installing the cooktops it must be taken into
account that the appliances only have 4 support points
and the height adjustment plates must be positioned
accordingly. This particularly applies to the Tepan
stainless steel grill CKT.
4.11.2 Securing the cooktop extractor
1
2
Fig. 4.27 Securing the cooktop extractor
[1] Tensioning screw
[2] Fixing bracket
XX
Turn the four fixing brackets [2] under the worktop.
XO
The fixing brackets are secured against slipping by a ratchet
mechanism.
XX
Tighten the tensioning screws [1] with max. 2 Nm.
XX
Do not use a cordless screwdriver or similar electrical device
to secure the cooktop extractor.
XX
Check that the cooktop extractor is positioned correctly.
4.10.2 Installing the additional fan
i
The maximum exhaust air duct length with a fan is 6m.
XX
Install an additional fan in the exhaust duct if necessary.
XX
Ensure that a minimum clearance of 3m is maintained
between the fan units.
XX
Use only BORA Universal fans.
If additional fans are installed at a later date:
XX
When installing additional fans at a later date, carry out the
initial operation procedure (see Initial operation).
XO
In the basic configuration, any fans installed at a later date
are automatically recognised provided that they have been
connected correctly. The system configuration is adjusted
accordingly.
4.11 Installing the cooktops
i
Clearance of one millimetre should be planned between
the appliances.
i
In the case of flush installation, a clearance of two
millimetres should be planned around the appliances.
XO
Cross bars on the kitchen unit in the area of the worktop cut-
out may need to be removed.
XO
The drawers and/or shelves in the floor unit must be
removable for maintenance and cleaning purposes.
XO
In the case of induction appliances, make sure that the area
below the cooktop is sufficiently ventilated. There should be
an opening cross-section > 50 cm² at the front side and in the
false floor for ventilation.
4.11.1 Fitting and positioning the cooktops
1
2
Fig. 4.25 Cooktop tted next to the cooktop extractor
[1] Cooktop extractor
[2] Cooktop
XX
Place the cooktop [2] next to the centrally-positioned cooktop
extractor [1].
XX
Align the cooktop [2] exactly.
XX
Push the cooktop [2] right up to the cooktop extractor [1].
XO
When the cooktop is pushed up against the side of the
cooktop extractor, spacers automatically provide the
prescribed 1 mm clearance.