Gas installation
www.bora.com
6.5 Handover to user
Once installation is complete:
Explain the main functions to the user.
Explain all safety-related aspects of operation and
handling to the user.
Provide the user with the accessories and operating
and installation instructions to be kept in a safe place.
6.6 Nozzle table
INFO Use only stamped and approved nozzles.
EU
Gas type/mbar Ø high-power burner Ø normal burner
G20/20 117 Y 75 X
G25/25 125 F3 73 F1
G30/30
G31/37
83 51
G30/50
G31/50
72 M 46 M
Tab. 6.2 Standard nozzle table
AUS/NZS
Gas type
LPG (liquid gas)
NG (natural gas)
Peak pressure
(kPa)
Gas burner
(position)
Nozzle diameter
1/100mm
Heat output
(MJ/n)
G30 butane LPG 2.75 Back 91 11.8
G31 propane LPG 2.75 Back 91 11.8
G20 natural gas NG 01:00 Back 155 12.0
G30 butane LPG 2.75 Front 53 4.4
G31 propane LPG 2.75 Front 53 4.4
G20 natural gas NG 01:00 Front 90 4.1
Tab. 6.3 Australia/New Zealand nozzle table