Installation and Operation Guide

EN
22
Gas installation
www.bora.com
6.4.1 Setting up gas taps
1
Fig. 6.4 Set the gas tap
[1] Throttling screw
Perform minimum setting:
Natural gas (NG)
Prerequisites:
Use of G20 nozzles.
It is not necessary to set up the primary air for the gas
burner.
Ignite the gas burner and set the control knob to the
minimum setting (small flame).
Remove the control knob by pulling it upwards.
Use a screw driver to turn the throttling screw [1] to
the right or left in order to adjust the flame correctly.
Put the control knob back on.
Ensure that the flame does not go out when changing
between the maximum and minimum setting on the
gas burner.
Liquid gas (LPG)
Prerequisites:
Use of G30/G31 nozzles.
The gas burners do not require the primary air to be set.
Remove the control knob by pulling it upwards.
Turn the throttling screw until it stops.
Put the control knob back on.
Ensure that the flame does not go out when changing
between the maximum and minimum setting on the
gas burner.
Changing the gas burner nozzle in the gas
burner:
Remove the pan support.
Remove the gas burner cover
1
2
Fig. 6.3 Cooktop burner with gas burner nozzle
[1] Gas burner
[2] Gas burner nozzle
Unscrew the gas burner nozzle [2] from the gas burner
[1]
Screw the corresponding nozzle for the gas type to be
used into the gas burner [2].
Position the gas burner cover correctly on the gas
burner [1] so that it lies flat.
Affix the new labelling for the gas type used (natural
gas/liquid gas) to the nameplate on the underside of
the appliance.
Install the corresponding gas connection for natural
gas (NG) or liquid gas (LPG). See the Gas connection
section in this chapter.