Installation and Operation Guide
EN
19
Gas installation
www.bora.com
6 Gas installation
Observe all safety and warning information (see the
Safety section).
Observe all national and regional laws and regulations,
as well as the supplementary regulations of the local
gas supply companies.
Follow the enclosed manufacturer‘s information.
INFO Taking into account the applicable valid
regulations, the cooktop must be connected
to the gas line with an upstream stopcock.
INFO The gas supply pipe can be connected after
the gas cooktop has been installed.
INFO The hose connection must be laid in such a way
that it is not subject to deformation, buckling or
abrasion.
INFO The stopcock and gas supply pipe connections
must be accessible.
INFO It must be possible to inspect the entire length of
the hose line once installed.
INFO Only compatible connection pieces are to be used
for the hose line.
INFO
The gas connection hose line must not come into
contact with smoke or the flue outlet of an oven.
INFO The hose line must not come into contact with hot
surfaces on the cooktop or other devices.
The gas connection may only be carried out by an
authorised gas fitter in accordance with applicable legal
and local regulations. Comply with local regulations of the
utility companies.
Country Regulation/guidelines
Germany DVGW-TRGI 2008 or TRF 1996
Austria ÖVGW guideline G1
Switzerland SvgW Gas Regulations G1
EKAS guideline no. 1942:
Liquid gas, part 2
Regulations of the Vereinigung Kantonaler
Feuerversicherungen (VKF)
Netherlands,
Belgium,
France
Regulations of standard NBN D 51-003
Regulations and connection requirements
of the gas supply company (G.D.F.) and
electricity supply company (E.D.F)
Australia,
New Zealand
AS/ANZS5601 – gas installation
Tab. 6.1 Country requirements (information supplied without
liability)
6.1 Ventilation
This appliance is not connected to a flue gas evacuation
device. It must be positioned and connected in
accordance with the applicable installation conditions.
Suitable ventilation measures must be adhered to in
particular.
Always ensure sufficient ventilation during operation
(of the appliance).
6.2 Gas connection
This gas cooking appliance corresponds to device class 3.
It is equipped with a flexible connection tube.
When using a gas connection, the following
instructions are not to be followed in Australia or
New Zealand.
The installation of a security gas socket in the adjacent
enclosure is recommended.
The connection of liquid gas (LPG) is performed with
the interconnection of a sealed connection socket pipe
D: 8x1mm.
The connection to the gas supply is to be created with
flexible and seamless pipes made from stainless steel.
The connection with a security gas socket is to be
created in accordance with DIN 3383 with a maximum
length of 1500 mm.
The connection bracket and connection pieces must
be equipped with a 1/2 inch external thread in
accordance with the regulatory country requirements
(see table 6.2 Connection bracket).