Installation and Operation Guide
EN
15
Installation
www.bora.com
Flush installation
x
(≥ 50)
A ±2
B ±2
519 ±2
≤ R5
≤ R5
≥ 50
495 ±2
≥ 600
Fig. 5.3 Flush installation
5 +0,5
12
10 – 40
Fig. 5.4 Groove dimensions cut-out
Cut-out dimensions when installing cooktops or cooktops
and the BORA cooktop extractor next to each other:
Cooktops/cooktop extractor A in mm B in mm
1/0 344 320
2/0 685 661
3/0 1026 1002
2/1 776 752
3/2 1208 1184
4/2 1549 1525
Tab. 5.2 Cut-out dimensions
5.3.3 Cooktop air intake
The components in the cooktop which generate heat are
automatically cooled. The warm air is extracted by fans
(cold air flow).
INFO In order to retain the full functionality of the
cooktop in the long term, there must be sufficient
ventilation underneath the cooktop.
INFO The performance of the cooktop is impaired or
the cooktop overheats if the warm air below the
cooktop cannot escape.
INFO If the cooktop overheats, performance is reduced
or the cooktop switches off completely (see
Overheating protection).
INFO For sufficient air intake, an opening cross-
section in the kitchen units of at least 50 cm
2
is
recommended.
Ensure there is sufficient ventilation underneath the
cooktop.
INFO The cable protection (false floor) must not prevent
sufficient ventilation.
> 20
50
Fig. 5.2 Side view of the cable protection and ventilation
5.4 Cut-out dimensions
INFO All dimensions from the front edge of the
front cover.
Please note the worktop overhang x when creating
the worktop cut-out. Applies to flush installation and
surface mounting.