Data Sheet
88
BASIC
245
290
89
Ø222
484
496
56
196
6
15,5
547
390
515
418
132242
760
275
471
BORA VENTILATION HANDBOOK
technical data
Maximum air volume 647 m³/h
Supply voltage 380 – 415 V 2N/3N
Supply voltage 220 – 240 V
Frequency 50 Hz
Maximum power consumption 7.6 kW (4.4 kW)
Fuse protection / power supply 3 x 16 A
Fuse protection / power supply 2 x 16 A
Fuse protection / power supply 1 x 32 A
Dimensions (WxDxH) 760 x 515 x 196 mm
Weight (incl. accessories/packaging) 25 kg
Connection on the exhaust side BORA Ecotube
Surface material SCHOTT CERAN
®
Power levels 1, 2, P
Power levels 1 – 9, P
Back cooking zone dimensions Ø 175 mm
Front cooking zone dimensions Ø 210 mm
Front cooking zone power 2300 W
Back cooking zone power 1400 W
Front cooking zone power setting 3000 W
Maximum static pressure 339 Pa
Product description
Minimum volume
Simple cleaning
Genuine stainless steel grease lter
Oversized 4 24 cooking surface
Compact size
childproong feature
Cooking zone timers
Timer
pan size recognition
Automatic after-run
Scope of delivery
Induction glass ceramic cooktop with BIA cooktop extractor
Stainless steel grease lter
BLAVH horizontal exhaust air extension
mounting straps
sealing tape
glass ceramic scraper
cable routing clips
height adjustment plate set
operating and installation instructions
Accessories
BFF stainless steel grease lter
BFIED air inlet nozzle
BUSU recirculation conversion set
UDB25 sealing tape
BKR760 cooktop frame
BLAVH1 exhaust air duct extension
product- and planning instructions
Basic cooktop extractor system can be combined with the sockets USTF,
USTE, USTJ, USTG and USTL
Please note that induction-compatible cookware must be used on induction
cooktops
The connection cable must be provided at the installation site
Front power socket
Max. exhaust channel length: 6 m
BIA
BORA Basic induction glass ceramic cooktop with integrated cooktop extractor - Exhaust air
BORA BASIC