Operating instructions

- 11 -
Cont ...
6 TECHNICAL SPECIFICATION
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
*Note: The maximum pressure that can be applied to the pump under any
installation conditions.
Pump Model
Flomate Mains
Boost Extra 100
46635
Flomate Mains
Boost Extra 200
46636
Flomate Mains
Boost Extra 300
46637
General
Guarantee 3 years
WRAS approval Approved material
Features
Pump type Peripheral
Mechanical seal Nitrile / Carbon / Silicon Carbide
Flexible hoses 2 2 2
Diaphragm tank size 100 litre 200 litre 300 litre
Diaphragm tank water capacity 50 litre 100 litre 150 litre
Dry run protection

Performance
Maximum head (closed valve) 3.2 bar
Maximum flow 18 l/min 24 l/min 30 l/min
Maximum working pressure* 450 kPa (4.5 bar)
Maximum ambient air temperature 40
o
C
Min / Max water temperature Min 4
o
C / Max 35
o
C
Flow switch sensitivity (approx) 0.6 l/min
Connections Pump connections G ¾ male
Flexible hoses Connections G ¾ female x 15 mm push-in x 200 mm long
Motor
Type Induction, auto-reset thermal trip
Duty rating Continuous
Electrical
Power supply / phase / frequency 230 V a.c. / 1 / 50 Hz
Current (full load) 1.7 Amps
Power consumption 365 Watts
Fuse rating 5 Amps
Power cable (pre-wired) 1.5 metres
Physical
Enclosure protection IPX4
Length 473 mm 564 mm
Width 432 mm 532 mm
Height (excluding hoses) 1134 mm 1388 mm 1843 mm
Weight (including fittings) 24.5 Kg 40 Kg 54 Kg