Flomate Mains Boost Extra Installation & Maintenance Instructions Please leave this instruction booklet with the owner as it contains important guarantee, maintenance and safety information Read this manual carefully before commencing installation. This manual covers the following products: Mains Boost Extra 100 Mains Boost Extra 200 Pt. No. 46635 Pt. No. 46636 Mains Boost Extra 300 Pt. No.
PRODUCT DESCRIPTION Electric motor driven peripheral pump with bypass, complete with an automatic control system consisting of flow switch, pressure vessel and electronic control. APPLICATION The Flomate is a mains booster unit with an automatic control system for domestic use, designed to assist the pressure from the mains supply, where the mains pressure is insufficient. This unit requires a minimum unassisted supply flow of 0.6 l/min to operate.
Care must be taken to ensure the maximum pressure generated by the pump combined with the incoming mains water pressure does not exceed the units maximum operating pressure of 4.5 bar. Please read installation details carefully as they are intended to ensure this product provides long, trouble free service. Failure to install the unit in accordance with the installation instructions will lead to invalidation of the warranty.
CHECKLIST IMPORTANT: With the pump removed from its packaging check for any damage prior to installation. If any damage is found contact Stuart Turner Ltd within 24 hours of receipt. C B C A Schrader valve Pressure vessel Fig. 1 Item Description Qty Item Description A Pump & tank assembly 1 C Washer 2 B Flexible hoses Qty 2 Your product may vary slightly from the picture above. Cont ...
1 IMPORTANT FACTS: READ BEFORE COMMENCING PUMP INSTALLATION A. Water temperature The water entering the pump must be controlled as follows: 1.11 The maximum allowable water temperature is 35 oC. 1.12 The minimum allowable water temperature is 4 oC. B. Pipework - General 1.13 Secure pipework: Ensure pipework to and from pump is independently supported & clipped to prevent forces being transferred to inlet and outlet branches of pump. 1.
2 LOCATION - GENERAL 2.11 Access: For emergencies and maintenance the pump must be easily accessible. 2.12 Protection: The pump must be located in a dry position, frost free and protected from freezing. Ensure the pump is in a dry position, away from heat sources, such as radiators and heaters. 2.13 Ventilation: Ensure an adequate air flow to cool the pump. Separate the pump from other appliances that generate heat.
2.19 Pipework Connections: Isolating valves: Always install isolating valves (not supplied) to both suction and delivery pipe to aid future maintenance. Typical installation Mains Boost Extra (in cupboard) Bypass (see note ‘b’ below) (Not supplied) Inlet (see note ‘a’ below) Mains water stop cock Mains water supply Fig. 2 a) Incoming mains pressure can vary, but must never exceed 2 bar. If there is a possibility of exceeding 2 bar, a separate inlet pressure control must be fitted.
3 ELECTRICAL INSTALLATION / EARTHING 3.16 3.17 3.18 3.19 3.11 Regulations: The electrical installation must be carried out in accordance with the current national electrical regulations and installed by a qualified person. 3.12 Safety: In the interests of electrical safety a 30 mA residual current device (R.C.D. not supplied) must be installed in the supply circuit. This may be part of a consumer unit or a separate unit. 3.
3.20 Wiring Diagram: The supply cord and internal wiring within the terminal box are routed and secured to ensure compliance with the electrical standard EN 60335-1. Do not disturb the internal wiring or factory routing and securing of all internal wiring. BLUE THERMOTRIP A M CAPACITOR BLACK BROWN LINK WIRE (BLUE) MAIN WINDING START WINDING N L BLUE BROWN GREEN/YELLOW N L E 230 VAC/1PH/50Hz SUPPLY N FLOWSWITCH REED (S2) S1 S2 S2 S1 FLOWSWITCH REED (S1) Fig. 4 3.
4 PRIMING 4.11 Priming: This pump unit is self venting. Open the mains stopcock and allow the pump to fill and vent, please note the pump chamber must be full of liquid at all times. Seal damage will result if the pump runs dry. 4.12 Starting: a) Ensure all outlets are closed, turn power supply ‘on’. b) Open and close all outlets in turn associated with the pump allowing liquid to flow from each outlet until all air is purged. c) The pump will run on while this is being completed until the vessel is full.
6 TECHNICAL SPECIFICATION Pump Model General Flomate Mains Flomate Mains Flomate Mains Boost Extra 100 Boost Extra 200 Boost Extra 300 46635 46636 46637 Guarantee 3 years WRAS approval Features Approved material Pump type Peripheral Mechanical seal Flexible hoses 2 2 2 Diaphragm tank size 100 litre 200 litre 300 litre Diaphragm tank water capacity 50 litre 100 litre 150 litre Dry run protection Performance Nitrile / Carbon / Silicon Carbide Maximum head (closed valve) Maximu
7 TROUBLE SHOOTING GUIDE Symptoms Probable Cause Recommended Action Pump will not start. No water. Check required flow of liquid is available to the fittings of approx. 0.6 l/min. Water supply. Check water supply from mains and all stopcocks are open. Electrical supply. Check wiring connections. If flow exists inline with requirements - check that all electric switches are on. Is the correct fuse fitted? Check circuit breaker is set. Reed switch is faulty and low water demand.
7.11 Flow Switch Circuit Test: 1. First confirm visually that neither of the flow switch reed clamps have been dislodged during handling or installation. The clamps must be fully located within their flow switch body grooves as shown. 2. To carry out the following test you will need to obtain a magnet, a typical fridge magnet is suitable. 3. Ensure the power supply is switched on. 4. Position the magnet directly in front of a reed clamp as shown.
8 THE FLOMATE GUARANTEE Congratulations on purchasing a Stuart Turner pump. We are confident this pump will provide many years of trouble free service as all our products are manufactured to the very highest standard. The Flomate Extra is guaranteed to be free from defects in materials or workmanship for 3 years from the date of purchase.
Installers – Register with Stuart Turner and move up to Approved Installer status We receive thousands of enquiries every month from people seeking a Stuart Turner installer and by registering your details with us, we can offer consumers the opportunity to quickly locate an installer in their area. Registration is free - simply click on the ‘register as an installer’ link on our homepage at www.stuart-turner.co.
DECLARATION OF CONFORMITY 2006/42/EC BS EN ISO 12100-1, BS EN ISO 12100-2, BS EN 809 2006/95/EC BS EN 60335-1, BS EN 60335-2-41 2004/108/EC BS EN 55014-1, BS EN 55014-2, BS EN 55022, BS EN 61000-3-2, BS EN 61000-3-3, BS EN 61000-4-2, BS EN 61000-4-3, BS EN 61000-4-4, BS EN 61000-4-5, BS EN 61000-4-6, BS EN 61000-4-11 1999/519/EC BS EN 62233 2011/65/EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW, COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E.E.C.