System information

Operation 475
sources is ignored. To manually reconfigure the attribute for an individual
parameter or attributes for all parameters to AUTO, use the Set to Factory
Default function.
If you enable DHCP, then the IP address, the subnet mask, the default
gateway, which the IP Phone obtains from the DHCP server, overwrites
the manually configured value. The value for EAP device ID and password
can also overwrite the manually configured value.
If you configure stickiness and the current provisioning source does not
provide the provisioning information for the particular parameter, the last
received provisioning value is used.
IP Phone reset
The IP Phone compares the provisioning information in the provisioning
files with the existing provisioning information. The IP Phone applies the
new provisioning information and then
resets silently
resets immediately during boot phase, DHCP phase, and provisioning
phase
resets in a few seconds during TPS connecting phase
If the IP Phone is idle, information appears on the display. If the IP
Phone is in an active call, the phone resets after the call ends.
Factory default
You can reset the following IP Phone parameters to the factory default
IP Phone 2007
IP Phone 1210
IP Phone 1220
IP Phone 1230
IP Phone 1110
IP Phone 1120E
IP Phone 1140E
IP Phone 1150E
Use [*][*][7][3][6][3][9] IP Phone MAC address [#][#] to reset the IP Phone
parameters to the factory default.
Table 120 "Factory default values" (page 476) shows the factory default
values for the IP Phone parameters.
Nortel Communication Server 1000
IP Phones Fundamentals
NN43001-368 05.02 26 May 2009
Copyright © 2003-2009 Nortel Networks. All Rights Reserved.
.