Specifications
6
NOTE: The TRACER is a negative ground controller. Any combination of
negative connections can be earth grounded as required. Grounding is
recommended.
CAUTION: Don’t connect DC-to-AC inverter to the TRACER directly because
the peak current of the inverter may exceed rated current of the controller when
the load turns on and will initiate short circuit protection.
CAUTION: The total current draw of all system loads connected to the
TRACER LOAD terminals cannot exceed the 10A load current rating. All the
loads surging current cannot exceed the 35A load current rating.
CAUTION: For mobile applications, be sure to secure all wiring. Use cable
clamps to prevent cables from swaying when the vehicle is in motion. Unsecured
cables create loose and resistive connections which may lead to excessive heating
and/or fire.
Step 1: Load Wiring
The TRACER load output can connect lights, pumps, motors, and other electronic
devices connection etc., TRACER will provide battery voltage to the loads. See
Section 4.4 Setting Operation for more details about the load control.
Figure 3-2 Load wiring