Specifications

18
·Load Short Circuit
Fully protected against load wiring short-circuit. After two automatic load
reconnect attempts (10 seconds between each attempt), the fault must be cleared by
removing and reapply power.
·High Voltage Input
If the solar input open circuit voltage (Voc) exceeds the maximum input voltage
of TRACER (TRACER 1206/60VDC; TRACER 1210/100VDC;
TRACER 1215/150VDC), the array will remain disconnected until the Voc falls safely
below the maximum rating.
·PV Reverse Polarity
Fully protection against PV reverse polarity, no damage to the controller will
result. Correct the miswire to resume normal operation.
·Battery Reverse Polarity
Fully protection against battery reverse polarity, no damage to the controller will
result. Correct the miswire to resume normal operation.
·Damaged Internal Temperature Sensor
If the temperature sensor short-circuited or damaged, the controller will be
charging or discharging at the default temperature 25 to prevent the battery damaged
from overcharging or over discharged.
·High-Voltage Transients
Solar, battery, and load power connections are protected against high voltage
transients. In lightning prone areas, additional external suppression is recommended.