4. Control of operating modes
After successfully turning on the device, the motor is controlled by two buttons of the radio remote control.
The signal from the radio remote control is received by the ANT1 and ANT2 antennas and is fed to the input of the WL1 receiver
and then fed to the PD2 input of the U2 controller, in which the signal is decoded.
There are two switching modes: for button A - Short Boost, for button B - Long Boost. All parameters of these modes are
configured through the application (APP). Pressing any button again while the motor is on will turn it off.
Parameters adjustable for Log Boost, button B:
The switch-on duration is set in the range of 1 - 999 seconds and the motor power in the range of 20 - 100%.
Also, to smoothly turn on and off the motor, you can set the number of steps for a gradually increasing motor power until the set
value is reached, up steps (2 - 20) and down steps (2 - 20) for a smooth motor stop. Time for one step 0,25sec.
All configured parameters are stored in the flash memory of the Atmega328P controller and are available after turning off and on.
Parameters adjustable for Short Boost, button A:
Short Boost has 3 work scenarios that are selected and configured from the application:
1. Smart 1 - the motor is switched on for the set duration and power.
2. Smart 2 - the motor performs a sequence of starts, first with the parameters of the Smart 1 mode, and then switches to the Smart 2
operating mode with the duration and power set for it.
3. Smart 3 - the motor performs a sequence of starts, first with the parameters of the Smart 1 mode, and then switches to the
operating mode with the Smart 2 parameters, then switches to the Smart 3 operating mode with the duration and power set for it.
For each of the modes, it is possible to set two parameters: the duration of switching on in the range of 1 - 60 seconds and the
motor power in the range of 20 - 100%.
To smoothly turn on and off the motor, you can set the number of steps for a gradually increasing motor power until the set value is
reached, up steps (2 - 20) and down steps (2 - 20) for a smooth motor stop. Time for one step 0,25sec. These parameters work as
follows: If Smart 3 is selected, then up steps are included before Smart 1 and down steps after Smart 3.
Only one of these scenarios can be assigned to button A, but it can always be changed through the application.