Operating instructions

58 08/06
5.2.1 Offset
In order to enable the start of a synchronous machine, the absolute position of the
rotor must be known. This information is required in order to actuate the stator wind-
ings in the right order depending on the position of the rotor. The position of the rotary
field in the synchronous machine must be controlled in order to obtain a continuous
movement of the rotor. During first commissioning, the position of the rotor windin
g
o
f
the resolver is adjusted to the rotor displacement angle of the synchronous motor b
y
ad
j
ustin
g
the offset. For operatin
g
a synchronous machine with resolver, the offse
t
must be adjusted in order to obtain perfectly true running and a maximum torque.
The correct
Offset 382 is adjusted when the flux-forming voltage 235 reaches the
value 0 (approximately) while the motor is turning.
Parameter Function
No. Description Min. Max. Fact. sett.
382 Offset -360.0° 360.0° 0.0°
The offset can be determined and adjusted as follows:
Durin
g
first commissionin
g
"SEtUP" will be displayed in the control unit. Press ESC
to stop this operation. The guided commissioning („SETUP“) is performed after ad-
justing the offset.
Open the parameter menu "PARA" and enter the machine data indicated on the
type plate or the data sheet of the motor.
Set parameter Operation Mode 380 to the frequency value of the field si
g
nal fo
r
the resolver.
Adjust parameter No. of Pole Pairs 381 to the number of pole pairs of the resolver.
Before adjusting the offset, take the following safety precautions:
Disable the frequency inverter via digital input S1IND (controller release).
If possible, uncouple the motor from the load so that the motor shaft turns freely. I
f
installed, release the mechanical brake.
If uncoupling is not possible, make sure that the motor is loaded as little as possi-
ble.
Warning! In certain circumstances, the motor speed may reach hi
g
h values. If the
motor is not uncoupled from the load, personal and material dama
g
e
may result. To avoid such dama
g
e, make the followin
g
settin
g
s in any
case.
Set the max. permissible output frequency of the frequency inverter to a low fre-
quency value via parameter
Switch-Off Limit 417. Select the frequency value such
that uncontrolled acceleration of the motor ("overspeedin
g
") is detected at an earl
y
stage. This limitation is necessary in order to avoid personal and material damage.
Set parameter Current Limit 728 of the speed controller to a low current value
(e.
g
. 10% of the rated motor current). In this way it is made sure that there are no
excessive currents of the offset is set incorrectly.