Operating instructions

11/068
8 11/06
The EM-SYS expansion module is supplied in a housin
g
for assembly on the lower slo
t
of the frequency inverter.
Remove the lower cover (1) of the frequency inverter.
The slot for the EM-SYS expansion module becomes accessible
1
Caution! The EM-SYS expansion module (2) is pre-fitted in a housin
g
. Do NO
T
touch the PCB visible on the back, as modules may be damaged.
Plug the EM-SYS expansion module (2) onto the slot (3).
2
3
Re-install the lower cover (1).
This completes the assembly procedure.
When the supply voltage of the frequency inverter is switched on, the EM-SYS expan-