Technical data
36
AGL202 - Technical data (from 0.12 to 2.2 kW)
AGL202- 02 03 05 07 09 11 13
Size 1
Output, motor side
Recommended motor power 3ph P
n
kW 0.25 0.37 0.55 0.75 1.1 1.5 2.2
Recommended motor power 1ph P
n
kW 0.12 0.18 0.25 0.37 0.55 0.75 1.1
Max.continuousoutputcurrent3ph I
n
A 1.5 2.0 3.0 3.5 5.0 6.0 9.0
Max.continuousoutputcurrent1ph I
n
A 1.0 1.3 1.5 2.0 3.0 3.5 5.0
Current overload 60 s I
OL
A 2.25 3.0 4.5 5.25 7.5 9.0 13.5
Current overload 1 s I
pk
A 3.0 4.0 6.0 7.0 10.0 12.0 18.0
Output voltage U
n
V Maxinputvoltage
Output frequency f
n
Hz ± 1000
Switching frequency f
c
kHz From 2 to 16
Protections - - Short circuit phase to phase / phase to earth
Input, mains side
Mainsconguration - - TT, TN, IT
Mainsratedvoltage U V 200…240
Mainsratedfrequency f Hz 50…60
Overvoltage category - - DIN EN 61800-5-1 300V CAT 3
General
Short circuit / earth protection - - Yes, unlimited
Mountingposition - - Vertical
Degree of protection - - IP 20 (EN 60529)
Dimensions
HxWxD
mm 200 x 60 x 170
Environment
Coolant temperature T
n
°C From0to40(40…55withderating)
Humidity - % 5…85,nocondensing
Options & accessories
Brake-chopper - - Integrated No
Line choke - - Option
EMIlter - - class A (EN 61800-3) integrated / class B option
Braking resistor - - Option
Operator panel - - Integrated
Communication interfaces - -
RS485Modbusintegrated/Systembusintegrated/CANopenintegrated
RS232 option / Profibus DP V1 option / DeviceNet option / EtherCAT
®
option /
ProfiNet option / VABus/TCP option