Technical data
30
General technical data
Environment
•Transportandstoragetemperature-25°C…55°C
•Operationtemperature:0°C-40°C(40°C-55°C
with derating)
•Environmentclass:3K3(EN60721-3-3)
•Relativehumidity5%...95%,nocondensation
•Altitudeofinstallation:upto3000m(over1000m
with derating)
•Storageconditions:accordingtoEN50178
•Degreeofprotection:IP20
Electrical
•
Ratedmainsvoltage3ph:intherange323….528V
•
Ratedmainsvoltage1ph:intherange200….240V
•Ratedmainsfrequency:intherange45…69Hz
•Overloadcurrent:150%nominalcurrent
•Peakcurrent:200%nominalcurrent
•Electricprotections:shortcircuit/earth
•Brakingtransistor:built-inonstandarddevice
Standards
•CEconformity:Lowvoltagedirective2006/95/EC
and EN50178 / DIN VDE 0160 and EN61800
•Interferenceimmunity:accordingtoEN61800-3
•ULapproval:accordingtoUL508c
•STO:61508/61800-5-2/13849
Connections
The Agile drive is fitted with power input
terminals for connection to the mains, power
output terminals for driving the motor and signal
terminals for inverter control, subdivided into four
sections.
Power terminals
The power terminals are located at the top and
bottom of the unit.
Mainsinputpowerisconnectedtothetopof
the drive where a DC-bus connection is also
provided. The power output cables to the motor
are connected to the bottom of the drive where
there is also a connection for a braking resistance
if required.
Just as on ACT and ACU drives, this effective
separation of input and output power terminals
helps prevent mis-wiring through human error.