Operating instructions

88 Application manual Positioning 04/08
Parameter Factory setting
1128 Start Phasing 7 - Off
Input and output signals of phasing function
Phasing
Output si
g
nals
Start Phasing
1128
Phasing: Offset
Phasing: Speed
Phasing: Acceleration
1125
1126
1127
Signal source:
616 - Phasing Done
Operation modes for digital outputs:
56 - Phasing Done
156 - Inv. Phasing Done
Input si
g
nals
Assign digital input signals or
logic signals to the parameter.
Example of phasing function:
1. Signal "Start Phasing" is set.
2. Acceleration at "Phasing: Acceleration" to "Phasing: Speed".
3. After offset by "Phasing: Offset", the digital signal "616 - Phasing Done" is set.
The signal is available as operation mode "56 - Phasing Done" for digital outputs.
Speed
Position
v
Master
Phasing: Acceleration
1127
Phasing: Offset
1125
Master position evaluated by the slave
physical master position
Phasing done
Start Phasing
Phasing: Speed
1126
Application manual Positioning 04/0888