Operating instructions
62 Application manual Positioning 04/08
4.4.2.5 Single motion
A signal on Start Positioning 1222 starts the Starting Record Number 1228 (pa-
rameter
Operation Mode 1221 in setting "202- single motion, motion block from p.
1228") or the motion block set via parameters
Motion Block Change-Over 1 1224
to
Motion Block Change-Over 5 1254, (parameter Operation Mode 1221 in setting
"201-single motion, motion block via digital inputs"). After completion of the motion,
the target position is maintained.
If operation mode "Speed" or an operation mode with el. gearing is selected for
Motion Mode 1208, the drive will continue to turn until the signal on Start Position-
ing
1222 is reset or interrupted by a signal on Stop Positioning 1223.
Single motion
Input si
g
nal
s
Operation Mode
1221
=
- 201 Single Motion,
Motion Block Sel. via Digital Inputs
Operation modes for
digital outputs:
160 - Inv. Arrived at
desired Position
60 - Target Position
Reached
- 202 Single Motion,
Motion Block Sel. via P. 1228
Assign digital input signals or
logic signals to the parameters.
Selection of the motion block:
Output si
g
nals
Signal source:
282 - Tar
g
et Position
Reached
Starting-Record Number
1228
Motion Block Change-Over 1
Motion Block Change-Over 2
Motion Block Change-Over 3
Motion Block Change-Over 4
Motion Block Change-Over 5
1224
1225
1226
1227
1254
Start Positioning
Stop Positioning
1222
1223
Application manual Positioning 04/0862