Operating instructions

60 Application manual Positioning 04/08
Set the next motion block, stop of the drive or error switch-off for an
event:
By entering one of the listed values for parameters
Delay: Next Motion Block 1213
Event 1: Next Motion Block 1215
Event 2: Next Motion Block 1217
Int.-Event 1: Next Motion Block 1262
Int.-Event 2: Next Motion Block 1265
the next motion block or user-defined behavior in the case of events can be se-
lected. Errors in the motion sequence can be identified quickly by emergency stop,
stop and the error switch-off function.
Next motion block
1213, 1215, 1217,
1262, 1265
Function
-3 -
(Minus 3)
Em. stop, error
The drive is stopped via
Emergency Ramp 1179,
after that, error message "F15XX User-Defined Error
in Motion Block" is output.
-2 -
(Minus 2)
Stop, error
The drive is stopped at the active deceleration ramp,
after that, error message "F15XX User-Defined Error
in Motion Block" is output.
-1 -
(Minus 1)
Error Switch-Off
The drive is switched off, after that, error message
"F15XX User-Defined Error in Motion Block" is out-
put.
0 - Disabled
Factory setting. Processing of next motion blocks
is switched off.
1 … 32 The corresponding motion block is executed.
Parameter Setting
No. Description Min. Max. Fact. sett.
1214 Event 1 Logic signal or digital input 7 - Off
1215 Event 1: Next Motion Block -3 32 0 - Disabled
1216 Event 2 Logic signal or digital input 7 - Off
1217 Event 2: Next Motion Block -3 32 0 - Disabled
1260
Interrupt
-Event 1
Logic signal or digital input 7 - Off
1261 Int.-Event 1: Eval.-Mode 1 6
1 - Level
Controlled
1262 Int.-Event 1: Next Motion Block -3 32 0 - Disabled
1263 Interrupt-Event 2 Logic signal or digital input 7 - Off
1264 Int.-Event 2: Eval.-Mode 1 6
1 - Level
Controlled
1265 Int.-Event 2: Next Motion Block -3 32 0 - Disabled