5.5.2 Actual speed source
If speed sensor 2 of the expansion module is confi
g
ured to supply the actual value
signal for the speed controller, speed sensor 2 must be selected as the source. Switch-
over is affected via parameter
Actual Speed Source 766. By default, speed sensor 1 is
used as the actual speed source.
Operation mode Function
1 -Speed sensor 1
The actual speed source is speed sensor 1 of the
basic device (factory setting).
2 -Speed sensor 2
The actual speed source is speed sensor 2 of the
EM-IO-02 expansion module.
5.5.3 Actual value comparison
The expansion module provides additional operation modes for parameters Operation
Mode Comparator 1
540 and Operation Mode Comparator 2 543 which are described
in the operatin
g
instructions. These operation modes permit a comparison of the speed
sensor 2 signal with the maximum speed and a comparison of the analog input EM-
S1INA with the maximum analog input value.
Operation mode Function
8 -
actual speed 2,
abs. value
Speed Sensor 2 Speed 220 > maximum speed (calcu-
lated from
Maximum Frequency 419 and
N
o. of Pole
P
airs 373)
16 -
Analog input
EM-S1INA, abs. value
A
nalog input EM-S1INA 253 > analog input 100%
108 and 116 Operation modes with signs (+/-)