Operating instructions
22
en
C) Operation with pre-heating
ButtonCisusedforswitchingthepre-heatingonandoff
(symbol Dlightsup).Asaresult,thewaterispre-heatedto
atemperatureof80°Cbeforeenteringthenebuliserspace.
Ittakesapprox.10to15minutesforthewaterinthebase
towarmup.Themistnowleavesthenebuliserspaceata
pleasanttemperatureof40°C.Theadvantageofthisis
thattheroomtemperaturedoesnotdropand,inaddition,it
significantlyimprovesthewaterqualitymaintenance.
D) Pre-heating Indicator
E) Empty indicator (red)
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewa-
tertankisempty.Theredemptyindicatorisilluminated
(symbolE).Pleasereadthechapter«Fillingthetank»for
moreinformation.TheredsymbolEmaystayilluminated
for some seconds with a refilled tank until the base is filled
withwater.
A) On-off switch
Turningtherotaryswitchclockwiseswitchestheappliance
onandatthesametimeregulatesthemistoutputfrom
lowtohigh.
B) Hygrostat (setting the humidity level)
Thedesiredhumiditylevelcanbesetbyturningtherotary
switchclockwise.Arelativehumiditybetween40and60%
isrecommended.Youcanachievethislevelbyrotatingthe
switchuntilitisroughlyintheverticalposition.Theaccu-
racyofmeasurementis+/-5%.Theunitwillswitchoff
whenthemoisturelevelexceedsthedesiredsetting.The
appliancedoesnotswitchoffiftheswitchisturnedallthe
waytotheright.Thisactivatesthecontinuousoperation
function.