SDS

3M Bondo® Glazing & Spot Putty 907, 907M, 907C, 907ES, 907W, 937, 937C 01/22/15
__________________________________________________________________________________________
Page 6 of 19
carcin
Acetone 67-64-1 OSHA TWA:2400 mg/m3(1000 ppm)
Dibutyl Phthalate 84-74-2 ACGIH TWA:5 mg/m3
Dibutyl Phthalate 84-74-2 OSHA TWA:5 mg/m3
ACGIH : American Conference of Governmental Industrial Hygienists
AIHA : American Industrial Hygiene Association
CMRG : Chemical Manufacturer's Recommended Guidelines
OSHA : United States Department of Labor - Occupational Safety and Health Administration
TWA: Time-Weighted-Average
STEL: Short Term Exposure Limit
CEIL: Ceiling
8.2. Exposure controls
8.2.1. Engineering controls
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure
Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment.
Use explosion-proof ventilation equipment.
8.2.2. Personal protective equipment (PPE)
Eye/face protection
Select and use eye/face protection to prevent contact based on the results of an exposure assessment. The following eye/face
protection(s) are recommended:
Indirect Vented Goggles
Skin/hand protection
Select and use gloves and/or protective clothing approved to relevant local standards to prevent skin contact based on the
results of an exposure assessment. Selection should be based on use factors such as exposure levels, concentration of the
substance or mixture, frequency and duration, physical challenges such as temperature extremes, and other use conditions.
Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible gloves/protective
clothing.
Gloves made from the following material(s) are recommended: Fluoroelastomer
Polymer laminate
Respiratory protection
An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of
a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator
type(s) to reduce inhalation exposure:
Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates
For questions about suitability for a specific application, consult with your respirator manufacturer.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
General Physical Form:
Liquid
Specific Physical Form:
Paste
Odor, Color, Grade:
Solvent Odor, Grean Smooth Paste
Odor threshold
No Data Available
pH
Not Applicable
Melting point
No Data Available
Boiling Point
132 ºF
Flash Point
63 ºF [Test Method: Closed Cup]
Evaporation rate
No Data Available