SDS
3M™ Bondo® Glazing & Spot Putty 907, 907M, 907C, 907ES, 907W, 937, 937C 06/01/18
__________________________________________________________________________________________
Page 6 of 18
Acetone
67-64-1
ACGIH
TWA:250 ppm;STEL:500 ppm
A4: Not class. as human
carcin
Acetone
67-64-1
OSHA
TWA:2400 mg/m3(1000 ppm)
Dibutyl Phthalate
84-74-2
ACGIH
TWA:5 mg/m3
Dibutyl Phthalate
84-74-2
OSHA
TWA:5 mg/m3
ACGIH : American Conference of Governmental Industrial Hygienists
AIHA : American Industrial Hygiene Association
CMRG : Chemical Manufacturer's Recommended Guidelines
OSHA : United States Department of Labor - Occupational Safety and Health Administration
TWA: Time-Weighted-Average
STEL: Short Term Exposure Limit
CEIL: Ceiling
8.2. Exposure controls
8.2.1. Engineering controls
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure
Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment.
Use explosion-proof ventilation equipment.
8.2.2. Personal protective equipment (PPE)
Eye/face protection
Select and use eye/face protection to prevent contact based on the results of an exposure assessment. The following eye/face
protection(s) are recommended:
Indirect Vented Goggles
Skin/hand protection
Select and use gloves and/or protective clothing approved to relevant local standards to prevent skin contact based on the
results of an exposure assessment. Selection should be based on use factors such as exposure levels, concentration of the
substance or mixture, frequency and duration, physical challenges such as temperature extremes, and other use conditions.
Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible gloves/protective
clothing.
Gloves made from the following material(s) are recommended: Butyl Rubber
Fluoroelastomer
Respiratory protection
An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part
of a full respiratory protection program. Based on the results of the exposure assessment, select from the following
respirator type(s) to reduce inhalation exposure:
Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates
For questions about suitability for a specific application, consult with your respirator manufacturer.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
General Physical Form:
Liquid
Specific Physical Form:
Paste
Odor, Color, Grade:
Solvent Odor, Red Smooth Paste
Odor threshold
No Data Available
pH
Not Applicable
Melting point
No Data Available
Boiling Point
132 ºF