SDS

3M™ Bondo® Glazing & Spot Putty 907, 907M, 907C, 907ES, 907W, 937, 937C 06/01/18
__________________________________________________________________________________________
Page 4 of 18
Immediately flush with large amounts of water for at least 15 minutes. Remove contact lenses if easy to do. Continue
rinsing. Immediately get medical attention.
If Swallowed:
Rinse mouth. If you feel unwell, get medical attention.
4.2. Most important symptoms and effects, both acute and delayed
See Section 11.1. Information on toxicological effects.
4.3. Indication of any immediate medical attention and special treatment required
Not applicable
SECTION 5: Fire-fighting measures
5.1. Suitable extinguishing media
In case of fire: Use a fire fighting agent suitable for flammable liquids such as dry chemical or carbon dioxide to extinguish.
5.2. Special hazards arising from the substance or mixture
Closed containers exposed to heat from fire may build pressure and explode.
5.3. Special protective actions for fire-fighters
Water may not effectively extinguish fire; however, it should be used to keep fire-exposed containers and surfaces cool and
prevent explosive rupture. Wear full protective clothing, including helmet, self-contained, positive pressure or pressure
demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering
for exposed areas of the head.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Evacuate area. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools.
Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or
exhaust vapors, in accordance with good industrial hygiene practice. Warning! A motor could be an ignition source and
could cause flammable gases or vapors in the spill area to burn or explode. Refer to other sections of this SDS for
information regarding physical and health hazards, respiratory protection, ventilation, and personal protective equipment.
6.2. Environmental precautions
Avoid release to the environment. For larger spills, cover drains and build dikes to prevent entry into sewer systems or
bodies of water.
6.3. Methods and material for containment and cleaning up
Cover spill area with a fire-extinguishing foam. An appropriate aqueous film forming foam (AFFF) is recommended.
Working from around the edges of the spill inward, cover with bentonite, vermiculite, or commercially available inorganic
absorbent material. Mix in sufficient absorbent until it appears dry. Remember, adding an absorbent material does not
remove a physical, health, or environmental hazard. Collect as much of the spilled material as possible using non-sparking
tools. Place in a metal container approved for transportation by appropriate authorities. Clean up residue with an
appropriate solvent selected by a qualified and authorized person. Ventilate the area with fresh air. Read and follow safety
precautions on the solvent label and SDS. Seal the container. Dispose of collected material as soon as possible in
accordance with applicable local/regional/national/international regulations.
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Do not use in a confined area with minimal air exchange. Keep out of reach of children. Do not handle until all safety
precautions have been read and understood. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use