Commissioning / Setup Setting up multiple appliances with the PNE Touch Pad Control www.climatetechnologies.com.
Multi-Appliance Touch Pad Multiple Unit Setup This instruction is for PNE touchpad controls connected to compatible Bonaire EAC and or Vulcan & Pyrox gas central heaters. The Bonaire EAC units compatible are fitted with the ā2003Sā control system. This will be indicated by the label on the control box inside the unit. The control box will also be Grey in colour. The Vulcan & Pyrox gas central heating units compatible are fitted with control boards that include an external reset button.
Multi-Appliance Touch Pad Multiple Unit Setup CODE / ZONE ALLOCATION OF ADDITIONAL UNITS Step 1 Turn the power on to the next appliance being coded. Check the green LED is visible. Step 2 Press and hold the RESET button in the control box (EAC) or on the control board (Gas Central Heating) for 25 seconds. At the 25 second mark, the green LED will start to flicker. Do not release the button at this point.
Multi-Appliance Touch Pad Multiple Unit Setup FORCED SCAN To force a scan for new equipment Step 1 Turn the touch pad ON Step 2 Turn the touch pad OFF and keep holding the ONOFF icon until the clock area shows - - - -. Release the ON-OFF button and the touch pad will scan for the new unit and re-initialise. Step 3 When the time clock returns to normal, turn the touch pad on and check the all the units have coded successfully.