Maintenance Requirements
1. Start Up Maintenance:-
With a new product there is the opportunity for new product residuals to
make their way into the water reservoir. After approximately 8 hours of
operation, check the following:-
Check and clean out any water blockage in the A/C6.
Check and clean out any water blockage in the water outlet
solenoid filter.
The unit tank / reservoir may need to be cleaned out. Remove the
over flow pipe and wash the tank out.
2. Annual Maintenance:-
Annual inspection of the water outlet and the CARE-FREE Water
Conditioner A/C 6 is recommended.
To clean the sacrificial anode, remove and soak it in vinegar for 5 –
10 minutes. Rinse off with water before reinstalling it.
If the anode is oxidized scrape clean. Replace the anode if
severely corroded.
The longevity of the anode is determined by the type of water it is
immersed in.
Check and clean out any water blockage in the A/C6.
Check and clean out any water blockage in the water outlet
solenoid filter.
Clean the unit tank / resevoir