Air Renewal Requirements:
When your cooler is working, it is important to leave a window or door open in order to keep a
constant air flow and to avoid any accumulation of humidity and heat. Your Evaporative Cooler
does not cool correctly when air flow is restricted from exiting a room. This causes a decrease in
the cooling efficiency due to an increase of humidity.
7. Maintenance
WARNING
Stagnant water may cause bacterial growth and serious health problems. Do not allow
stagnant water to remain in the tank.
Drain and clean the water tank before storage, after seasonal use and whenever the unit is
not used for a long time period.
Changing the filter pads:
Please follow the instructions below in order to change the filter pads.
1- Remove the two screws (as shown by arrows).
2- Pull the panel from the top as shown in in the image.
3- Filter pads are secured by a bracket with 3 screws, remove 3 x screws as shown to be able
to remove filter pad, replace filter pads.
1
2
2
Remove Screw
Remove Screw
Remove Screw
Remove Screw
Remove Screw
3
3