4. Allow the engine to run for an additional 2 minutes
5. Switch off the engine, wait 5 minutes to allow the oil to drain back to the oil pan.
6. Check the oil level, and if necessary, top off with oil to the “Max” mark on the
dipstick.
3.1.2. Adding Fuel
Use only commercial-grade diesel fuel. For fuel grade, see section 4.2. Use summer or
winter-grade fuel, depending on the ambient temperature.
Never fill the tank while the engine is running.
Ensure cleanliness!
Do not spill fuel!
DO NOT use BIO-DIESEL; bio-diesel can cause the fuel
injection components to stick if the engine is not run for an
extended period of time.
3.1.3. Other Preparations
Check battery and cable connectors, (see section 6.7.1)
Remove Transport Shackles, if fitted: (see section 6.7.3)
After all engine preparations have been done conduct a trial run for about 10
minutes with the engine UNLOADED.