Manual

23
Use serial control over Dante AV network, you need to setup Serial Config and run routing check within Dante
Controller.
Set up Serial Config Tab within Dante Controller
Dante Controller serial RS422 routing check.
The 'RS-422' ancillary channel on the Bolin-PTZ-Camera-D220 receiver is subscribed to the equivalent
channels on the Bolin-Decoder-D10H transmitter.
These subscriptions would enable serial control RS-422 on the transmitter (decoder) via the Serial control
ports RS-422 on the receiver (camera).
The 'RS-422' ancillary channel on the Bolin-Decoder-D10H receiver is subscribed to the equivalent
channels on the Bolin-PTZ-Camera-D220 transmitter.
These subscriptions would enable serial control RS-422 on the transmitter (camera) via the Serial control
ports RS-422 on the receiver (decoder).
It is not needed to use IR subscription when you use Bolin Dante AV camera and Bolin Dante AV
decoder.