Use serial control over Dante AV network, you need to setup Serial Config and run routing check within Dante
Controller.
• Set up Serial Config Tab within Dante Controller
Dante Controller serial RS422 routing check.
• The 'RS-422' ancillary channel on the Bolin-PTZ-Camera-D220 receiver is subscribed to the equivalent
channels on the Bolin-Decoder-D10H transmitter.
These subscriptions would enable serial control RS-422 on the transmitter (decoder) via the Serial control
ports RS-422 on the receiver (camera).
• The 'RS-422' ancillary channel on the Bolin-Decoder-D10H receiver is subscribed to the equivalent
channels on the Bolin-PTZ-Camera-D220 transmitter.
These subscriptions would enable serial control RS-422 on the transmitter (camera) via the Serial control
ports RS-422 on the receiver (decoder).
• It is not needed to use IR subscription when you use Bolin Dante AV camera and Bolin Dante AV
decoder.