User`s manual
S2000-К Operating
17 www.bolid.com
Using the t and u buttons, it is possible to review if there are
other non-armed zones in the partition.
To return the display back to indicate the partition status and to
proceed to the other partitions press CLEAR or ENTER.
Partition Disarming Procedure
Switch the S2000-К if necessary into the Time Display mode. If the
presented authenticator is intended not only to arm/disarm but also
to gain access, press the ON button to switch the display to the
Command Input mode. Type four-digit user password on the S2000-
К keypad or present your electronic access device to a reader which
is assigned to this S2000-K keypad.
If entered password (presented access device) is not identified by
the network controller, the S2000-K produces the Error beep and
displays the ILLEGAL CODE message followed by switching to the
Time Display mode. After thrice-repeated entering of invalid
passwords the keypad blocks password inputting for 30 seconds.
If the password (electronic access device) is correct, the keypad
displays the status of the first partition accessible to the user. The
example shows the 1200 partition being in the ARMED status.
Select the proper partition using t and u buttons or enter the
number by the keypad buttons, and then press ENTER.
To disarm the partition select vDISARMING from the command
menu and press ENTER.
If partition disarming was successful, the keypad produces the
Success beep and displays the new partition status:
v1200: DISARMED. In case of negative result the keypad will
produce the Error beep and display an error message such as
WRONG PARTITION or FAILED.
v 1200: ARMED
vDISARM
ENTER CODE: